LC-quadrupole/Orbitrap high-resolution mass spectrometry enables stable isotope-resolved simultaneous quantification and 13C-isotopic labeling of acyl-coenzyme A thioesters

Abstract: Acyl-coenyzme A thioesters (acyl-CoAs) are evolutionarily conserved, compartmentalized, and energetically activated substrates for biochemical reactions. The ubiquitous involvement of acyl-CoAs in metabolism, including the tricarboxylic acid cycle, fatty acid metabolism, amino acid degradation, and cholesterol metabolism highlights the broad applicability of applied measurements of acyl-CoAs. However, quantitation of acyl-CoA levels provides only one dimension of metabolic information and a more complete descr… Show more

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
1
1
1

Citation Types

0
82
0

Year Published

2016
2016
2019
2019

Publication Types

Select...
6
2
2

Relationship

6
4

Authors

Journals

citations
Cited by 82 publications
(82 citation statements)
references
References 36 publications
0
82
0
Order By: Relevance
“…For quantitation, internal standards containing [ 13 C 3 15 N 1 ]-labelled acyl-CoAs generated in pan6 -deficient yeast culture (Snyder et al, 2015) were added to each sample in equal amounts. Samples were analyzed by an Ultimate 3000 autosampler coupled to a Thermo Q Exactive Plus instrument in positive ESI mode using the settings described previously (Frey et al, 2016). A more detailed method can be found in the Supplemental Material.…”
Section: Methodsmentioning
confidence: 99%
“…For quantitation, internal standards containing [ 13 C 3 15 N 1 ]-labelled acyl-CoAs generated in pan6 -deficient yeast culture (Snyder et al, 2015) were added to each sample in equal amounts. Samples were analyzed by an Ultimate 3000 autosampler coupled to a Thermo Q Exactive Plus instrument in positive ESI mode using the settings described previously (Frey et al, 2016). A more detailed method can be found in the Supplemental Material.…”
Section: Methodsmentioning
confidence: 99%
“…Liquid Chromatography-Mass Spectrometry-Samples were analyzed by an Ultimate 3000 autosampler coupled to a Thermo Q Exactive Plus instrument in positive electrospray ionization mode in 10-l injections using settings described previously (41). Analytes were separated before introduction to the mass spectrometer using a Waters HSS T3 column (2.1 ϫ 100 mm, 3.5-m particle size) with 5 mM ammonium acetate in water as solvent A, 5 mM ammonium acetate in acetonitrile/ water (95:5, v/v) as solvent B, and acetonitrile/water/formic acid (80:20:0.1, v/v/v) as solvent C. Gradient conditions were as follows: 2% B for 1.5 min, increased to 25% over 3.5 min, increased to 100% B in 0.5 min and held for 8.5 min, and washed with 100% C for 5 min before equilibration for 5 min.…”
Section: Determination Of Acyl-coa Speciesmentioning
confidence: 99%
“…Instruments combining HR/AM MS capabilities with more traditional isolation and fragmentation capabilities, including the quadrupole/Orbitrap or quadrupole/time-of-flight (TOF) hybrid instruments, can provide sensitive, specific quantification through multiple modes of mass spectrometry at scan speeds increasingly compatible with liquid chromatography. In hybrid instruments equipped with a mass filter to select precursor ions, a fragmentation cell, and then a high resolution mass analyzer, MS/HRMS analysis can also be performed [14]. The product ion chromatograms can be extracted from the MS/high-resolution MS data using a narrow mass tolerance (<5 ppm) commensurate with the mass accuracy of the analyzer, the resolution of the instrument and the complexity of the matrix.…”
Section: Introductionmentioning
confidence: 99%