2005
DOI: 10.1016/j.jchromb.2005.04.015
|View full text |Cite
|
Sign up to set email alerts
|

LC/MS/MS measurement of gentamicin in bovine plasma, urine, milk, and biopsy samples taken from kidneys of standing animals

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
1
1
1
1

Citation Types

1
47
0

Year Published

2005
2005
2013
2013

Publication Types

Select...
9
1

Relationship

0
10

Authors

Journals

citations
Cited by 78 publications
(48 citation statements)
references
References 12 publications
(21 reference statements)
1
47
0
Order By: Relevance
“…A portion was removed for protein content determination by the methods of Bradford et al [23] and samples were centrifuged at 4⁰C for 5min at 14,000rpm. Intracellular gentamicin was detected by LC-MS/MS in multiple-reaction monitoring mode (MRM) with the main working parameters and product ion scanning based on methods described previously [24]. Analyses were performed using an Applied Biosystems/MDS Sciex Coefficient of variation calculated from 5 standard curves ran on 5 separate days was <10%…”
Section: Gentamicin Intracellular Quantification By Lc-ms/msmentioning
confidence: 99%
“…A portion was removed for protein content determination by the methods of Bradford et al [23] and samples were centrifuged at 4⁰C for 5min at 14,000rpm. Intracellular gentamicin was detected by LC-MS/MS in multiple-reaction monitoring mode (MRM) with the main working parameters and product ion scanning based on methods described previously [24]. Analyses were performed using an Applied Biosystems/MDS Sciex Coefficient of variation calculated from 5 standard curves ran on 5 separate days was <10%…”
Section: Gentamicin Intracellular Quantification By Lc-ms/msmentioning
confidence: 99%
“…These methods used liquid chromatography/tandem mass spectrometry (LC/MS/MS) to measure penicillin concentrations to fairly low levels. 1 These methods were applied to the tissue-fluid correlation studies mentioned above. 2 A novel laparoscopic surgical technique was used to obtain kidney cortex samples from standing animals.…”
mentioning
confidence: 99%
“…A gradient separation was achieved for vancomycin with a starting A:B ratio of 100:0 at a flow rate of 0.3 mL/minute. The described conditions for gentamicin were used by Heller et al [18], where the coeluted gentamicin components C1, C2, C2a and C1a were detected simultaneously. The apparatus used for detection of all three antibiotics was an API 4000 QTrap (Applied Biosystems, Darmstadt, Germany).…”
Section: Methodsmentioning