2021
DOI: 10.1016/j.jchromb.2021.122654
|View full text |Cite
|
Sign up to set email alerts
|

LC-MS/MS analysis of vitamin D3 metabolites in human serum using a salting-out based liquid-liquid extraction and DAPTAD derivatization

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
4
1

Citation Types

0
5
0

Year Published

2022
2022
2023
2023

Publication Types

Select...
7

Relationship

1
6

Authors

Journals

citations
Cited by 10 publications
(5 citation statements)
references
References 41 publications
0
5
0
Order By: Relevance
“…123 For analyzing the VD metabolites, LC-MS/MS has appeared as a more reliable method with improved sensitivity and specificity. 124 Unfortunately, due to the lipophilic character of these molecules and the lack of functional groups that assist ionization, quantitative measurement of VD by mass spectrometry is difficult. 125 A typical strategy for improving the ionization efficiency of the molecules is to use a derivatization procedure and Cookson-type reagents are generally used to react with VD in the Diels–Alder cycloaddition reaction.…”
Section: Methodsmentioning
confidence: 99%
See 1 more Smart Citation
“…123 For analyzing the VD metabolites, LC-MS/MS has appeared as a more reliable method with improved sensitivity and specificity. 124 Unfortunately, due to the lipophilic character of these molecules and the lack of functional groups that assist ionization, quantitative measurement of VD by mass spectrometry is difficult. 125 A typical strategy for improving the ionization efficiency of the molecules is to use a derivatization procedure and Cookson-type reagents are generally used to react with VD in the Diels–Alder cycloaddition reaction.…”
Section: Methodsmentioning
confidence: 99%
“…High sensitivity and specicity 141 Expensive instrumentation and a high level of technical expertise are required 142 No cross-reactions lead to overestimation and simultaneous measurements of different VD metabolites 125 Susceptible to ion suppression interference 124…”
Section: Lc-msmentioning
confidence: 99%
“…LC‐MS/MS was used to detect the contents of vitamin A, vitamin C, vitamin D, and vitamin E in serum 13,14 . The standard vitamin, mobile phase formic acid, and methanol were purchased from Merck.…”
Section: Methodsmentioning
confidence: 99%
“…LC‐MS/MS was used to detect the contents of vitamin A, vitamin C, vitamin D, and vitamin E in serum. 13 , 14 The standard vitamin, mobile phase formic acid, and methanol were purchased from Merck. The LC‐MS/MS platform connects the Shimadzu® Nexera X2 high performance liquid chromatograph (Shimadzu USA) with the AB Sciex® 6500 + triple quadrupole mass spectrometer (Sciex).…”
Section: Methodsmentioning
confidence: 99%
“…The 24,25(OH) 2 D 3 concentrations were analyzed in cell culture samples from Section 2.4.3 , using DAPTAD derivatization and LC-MS/MS, as previously described [ 38 ]. The calibrators were prepared in phosphate-buffered saline (PBS), and the samples were appropriately diluted with PBS to bring them into the linear range of the assay.…”
Section: Methodsmentioning
confidence: 99%