Bracing Cold-Formed Steel Structures 2005
DOI: 10.1061/9780784408179.apc
|View full text |Cite
|
Sign up to set email alerts
|

Lateral Bracing of Columns and Beams

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
3
1
1

Citation Types

0
49
0
1

Year Published

2006
2006
2021
2021

Publication Types

Select...
7
2

Relationship

0
9

Authors

Journals

citations
Cited by 27 publications
(50 citation statements)
references
References 0 publications
0
49
0
1
Order By: Relevance
“…Many bracing provisions for the stiffness are based on a requirement to limit the amount of twist at the design load to a value equal to the initial imperfection (corresponds to a total twist/initial twist value of 2.0). An adequate bracing system must possess sufficient strength and stiffness to support the design loads and control deformations (Winter 1960). For Grade 345 MPa (Grade 50) steel during construction, a maximum bending stress level of 200 MPa (29 ksi) would likely be a reasonable limit for steel I-girder bridges.…”
Section: Buckling Test Results Of W762 × 134 (Us-w30 × 90) Twin-girdementioning
confidence: 99%
“…Many bracing provisions for the stiffness are based on a requirement to limit the amount of twist at the design load to a value equal to the initial imperfection (corresponds to a total twist/initial twist value of 2.0). An adequate bracing system must possess sufficient strength and stiffness to support the design loads and control deformations (Winter 1960). For Grade 345 MPa (Grade 50) steel during construction, a maximum bending stress level of 200 MPa (29 ksi) would likely be a reasonable limit for steel I-girder bridges.…”
Section: Buckling Test Results Of W762 × 134 (Us-w30 × 90) Twin-girdementioning
confidence: 99%
“…In this study, we indicate that the initial curvature of the column and a lateral support element remain in its elastic limit. Winter articulated adopted as the support member ports in subsequent studies [16]. In this study, internal force on the support element due to the elastic load in the column was determined and the minimum stiffness.…”
Section: Analytical Studymentioning
confidence: 99%
“…Significant work has been conducted on sheathing-braced cold-formed steel stud walls, Okasha (2004), Fiorino et al (2007), and Chen et al (2006) have concentrated their efforts in determining the resistance of the stud-to-sheathing connection; while Miller and Pekoz (1993), Winter (1960), and Simaan and Pekoz (1976) have specifically investigated fastener demands. The commentary of AISI-S211 (2007), based on the research conducted by Winter (1960), states that a fastener-sheathing assembly shall be designed for a load equal to 2% of the axial load, also know as "2% rule".…”
Section: Introductionmentioning
confidence: 99%
“…The commentary of AISI-S211 (2007), based on the research conducted by Winter (1960), states that a fastener-sheathing assembly shall be designed for a load equal to 2% of the axial load, also know as "2% rule".…”
Section: Introductionmentioning
confidence: 99%