2008
DOI: 10.1016/j.jvs.2008.02.002
|View full text |Cite
|
Sign up to set email alerts
|

Late complication from a retrievable inferior vena cava filter with associated caval, aortic, and duodenal perforation: A case report

Abstract: Inferior vena cava filters are an excellent therapeutic method for those patients in whom anticoagulant therapy is contraindicated or ineffective. However, filter placement is associated with a high rate of serious complications (>30%), with death occurring in 3.7% of patients. The most common complication is an asymptomatic inferior vena cava penetration and perforation. In some rare circumstances, however, therapeutic intervention may be required because of perforation of adjacent organs. We report a clinica… Show more

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
1
1
1

Citation Types

1
37
0

Year Published

2009
2009
2019
2019

Publication Types

Select...
6
1

Relationship

0
7

Authors

Journals

citations
Cited by 47 publications
(39 citation statements)
references
References 20 publications
1
37
0
Order By: Relevance
“…33,34 For cases in which the filter is not removed, follow-up CT scans are appropriate. 35 Removal of permanent filters such as Greenfield, VenaTech, and Bird's Nest filters is technically challenging because these filters are not designed to be retrieved. Although surgical filter retrieval has been reported, 36 conservative management including observation and analgesia is the usual management for non-life-threatening penetrations.…”
Section: -13mentioning
confidence: 99%
“…33,34 For cases in which the filter is not removed, follow-up CT scans are appropriate. 35 Removal of permanent filters such as Greenfield, VenaTech, and Bird's Nest filters is technically challenging because these filters are not designed to be retrieved. Although surgical filter retrieval has been reported, 36 conservative management including observation and analgesia is the usual management for non-life-threatening penetrations.…”
Section: -13mentioning
confidence: 99%
“…The patient underwent endoscopy, which revealed a non-hemorrhagic erosion within the proximal duodenum, with swelling associated with a metallic foreign body, a strut of the patient's Bird's Nest IVC filter [50]. Additional cases of IVC filter perforation of the duodenum have been reported [51]. In a review of the literature, of 37 reported cases of duodenocaval fistulas, 10 were associated with an IVC filter [51], although duodenal perforations are usually asymptomatic [50].…”
Section: Perforationmentioning
confidence: 99%
“…Additional cases of IVC filter perforation of the duodenum have been reported [51]. In a review of the literature, of 37 reported cases of duodenocaval fistulas, 10 were associated with an IVC filter [51], although duodenal perforations are usually asymptomatic [50]. Fig.…”
Section: Perforationmentioning
confidence: 99%
“…Factors such as route and technique, indication for placement, category/ size of filter and timing of retrievable filters should also be taken into consideration to decrease rate of complications. Complications of IVC filters are numerous pulmonary embolism, duodenal and aortic perforations, caval thrombosis, post thrombotic syndrome, migration to right atrium, right ventricle and pulmonary artery and should not be ignored [1,4]. Less than 30 cases of IVC filter fracture with cardiac migration has been reported in the literature [5][6][7].…”
Section: Discussionmentioning