2021
DOI: 10.1016/j.mvr.2020.104072
|View full text |Cite
|
Sign up to set email alerts
|

Laser speckle contrast analysis (LASCA) technology for the semiquantitative measurement of angiogenesis in in-ovo-tumor-model

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
4
1

Citation Types

0
20
0

Year Published

2021
2021
2023
2023

Publication Types

Select...
7
1

Relationship

3
5

Authors

Journals

citations
Cited by 20 publications
(20 citation statements)
references
References 48 publications
0
20
0
Order By: Relevance
“…The 3D in vivo tumour model (CAM, chorioallantoic membrane) was carried out as described in previous publications ( Feder et al, 2020 ; Pion et al, 2020 ; Troebs et al, 2020 ). Fertilized chicken eggs were incubated in a ProCon egg incubator (Grumbach) at 37.8°C and 63% humidity under hourly rotation for a 4-d period until a window of ∼1 × 1 cm was cut into the eggshell and sealed again with tape.…”
Section: Methodsmentioning
confidence: 99%
“…The 3D in vivo tumour model (CAM, chorioallantoic membrane) was carried out as described in previous publications ( Feder et al, 2020 ; Pion et al, 2020 ; Troebs et al, 2020 ). Fertilized chicken eggs were incubated in a ProCon egg incubator (Grumbach) at 37.8°C and 63% humidity under hourly rotation for a 4-d period until a window of ∼1 × 1 cm was cut into the eggshell and sealed again with tape.…”
Section: Methodsmentioning
confidence: 99%
“…The Chick Chorioallantoic Membrane (CAM) model was performed as described before [ 11 , 26 , 27 ]. Two days after implantation of 2 × 10 6 Merkel cell carcinoma cells (WaGa and MKL-1), daily treatment with either Na + -gluconate (500 mg/kg/d) or NaCl 0.9% was performed ( n = 20).…”
Section: Methodsmentioning
confidence: 99%
“…The CAM model was performed as previously described [ 24 , 25 , 26 , 27 ]. Upon arrival, chicken eggs were disinfected with ethanol (70%) and placed in a ProCon egg incubator (Grumbach, Asslar, Germany) at 37.8 °C and 63% humidity in combination with hourly rotation.…”
Section: Methodsmentioning
confidence: 99%
“…LSCI is a semi-quantitative method which can be used to measure microcirculatory blood perfusion based on the fluctuations of the contrast in a speckle pattern that is caused by the backscattering of laser arrays due to the movement of erythrocytes in the blood vessels. The PeriCAM perfusion speckle imager (PSI) system high resolution (HR) model (PERIMED, Netherlands) was used for LSCI measurements adjacent to the previously described protocol, and the average perfusion rate was calculated by the PimSoft version 1.5 software [ 25 ]. Minor deviations from the previously described protocol included an increased sampling frequency of 44 Hz, which increased the number of images that were used to calculate an average for one measurement to 88.…”
Section: Methodsmentioning
confidence: 99%
See 1 more Smart Citation