Laser resonance ionization mass spectrometry measurements of cesium in nuclear burn-up and sediment samples

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
1
1
1

Citation Types

0
64
0

Year Published

2005
2005
2022
2022

Publication Types

Select...
4
2

Relationship

0
6

Authors

Journals

citations
Cited by 36 publications
(65 citation statements)
references
References 7 publications
0
64
0
Order By: Relevance
“…Comparing with the GM counter, the background count rate is higher in LSC, the lowest count rate measured using the commercial Quantulus Ultra low-level LSC produced by Wallac, PerkinElmer is around 0.5 counts per minute (CPM) for the 3 H window and 1.5 CPM for the 99 Tc window while the background for the anticoincidence shielded GM counter may be as low as 0.1-0.2 CPM, this makes the detection limit of LSC is worse than using low level GM counters (Table 4). In addition, the quench correction is another drawback of LSC, which requires an extra work for acquiring accurate results.…”
Section: Beta Countingmentioning
confidence: 98%
See 4 more Smart Citations
“…Comparing with the GM counter, the background count rate is higher in LSC, the lowest count rate measured using the commercial Quantulus Ultra low-level LSC produced by Wallac, PerkinElmer is around 0.5 counts per minute (CPM) for the 3 H window and 1.5 CPM for the 99 Tc window while the background for the anticoincidence shielded GM counter may be as low as 0.1-0.2 CPM, this makes the detection limit of LSC is worse than using low level GM counters (Table 4). In addition, the quench correction is another drawback of LSC, which requires an extra work for acquiring accurate results.…”
Section: Beta Countingmentioning
confidence: 98%
“…This is mainly achieved by reducing the background count rate of the detector by using heavy lead shielding and a GM guard detector above the sample detectors, operating in anticoincidence mode with the sample detector(s). A background count rate of 0.1 counts per minute was reported for a commercial low-level GM counter produced at Risø National Laboratory, Denmark, and the detection limit reported is less than 1.5 mBq for 99 Tc and 90 Sr [15][16][17]. Table 4 lists radionuclides typically measured by beta counting and their approximate detection limits.…”
Section: Beta Countingmentioning
confidence: 99%
See 3 more Smart Citations