Laser‐induced quenched phosphorescence detection in capillary electrophoresis

Abstract: The feasibility of laser-based excitation for quenched phosphorescence detection in capillary electrophoresis (CE) was explored for the first time by using a small-size, quadrupled Nd-YAG laser emitting 266 nm pulses (duration, 0.4 ns) at a repetition rate of 7.8 kHz. To provide a continuous phosphorescence background, the phosphorophore 1-bromo-4-naphthalene sulfonic acid (BrNS) was added to the separation buffer. Both experiments and theory show that in laser-induced phosphorescence (LIP) - in contrast with … Show more

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
1
1

Citation Types

1
3
0

Year Published

2003
2003
2011
2011

Publication Types

Select...
5
1

Relationship

3
3

Authors

Journals

citations
Cited by 6 publications
(4 citation statements)
references
References 6 publications
1
3
0
Order By: Relevance
“…These observations indicate that the effect requires high concentrations of the (+)-CQ complex with α-CD in the T 1 -state. Therefore, most probably it can be attributed to triplet−triplet annihilation . In agreement with this interpretation, the lifetime of (−)-CQ is less affected by this phenomenon (see Figure a).…”
Section: Resultssupporting
confidence: 80%
“…These observations indicate that the effect requires high concentrations of the (+)-CQ complex with α-CD in the T 1 -state. Therefore, most probably it can be attributed to triplet−triplet annihilation . In agreement with this interpretation, the lifetime of (−)-CQ is less affected by this phenomenon (see Figure a).…”
Section: Resultssupporting
confidence: 80%
“…The basic instrumentation is the same as for LIF detection [114] but a UV-Vis lamp has usually been employed [115][116][117][118]. There are two additional settings in phosphorescence not used in fluorescence: the delay time (time of waiting after the lamp pulse to remove all fluorescence from the signal) and the gating time (time of measurement of the phosphorescence signal), which have to be considered.…”
Section: Alternative Detection Systems To On-column Uv-vis Absorptionmentioning
confidence: 99%
“…Therefore, indirect phosphorescence in sensitized and quenched mode was explored. For this purpose, the phosphorophores BrNS and CQ were tested; both compounds have been used extensively in earlier studies [19, 2123, 26, 28, 40, 41]. In the sensitized phosphorescence mode, MTX, is excited and transfers its excitation energy to BrNS or CQ, of which the phosphorescence is then observed.…”
Section: Resultsmentioning
confidence: 99%