2016
DOI: 10.1016/j.biosystemseng.2016.02.010
|View full text |Cite
|
Sign up to set email alerts
|

Laser-induced fluorescence spectroscopy applied to early diagnosis of citrus Huanglongbing

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
1
1
1
1

Citation Types

4
34
0
1

Year Published

2016
2016
2023
2023

Publication Types

Select...
7
1

Relationship

0
8

Authors

Journals

citations
Cited by 32 publications
(39 citation statements)
references
References 24 publications
4
34
0
1
Order By: Relevance
“…They represent the characteristic emission of chlorophyll fluorescence (ChlF). [23][24][25][37][38][39][40] Figure 4 shows the typical fluorescence spectra obtained with the LIFS-561 system, where the two emission peaks, at 680 nm and 730 nm, are characteristic of chlorophyll fluorescence emission (CHlF). [26][27][28][29]40 Figures 5 and 6 show the score plot for three PCs, PC1 Â PC2 Â PC3, of PCA analysis using the fluorescence spectra (LIFS-405 and LIFS-561, respectively) of leaves from different Pera sweet orange accessions grafted in Rangpur lemon rootstock.…”
Section: Resultsmentioning
confidence: 99%
See 2 more Smart Citations
“…They represent the characteristic emission of chlorophyll fluorescence (ChlF). [23][24][25][37][38][39][40] Figure 4 shows the typical fluorescence spectra obtained with the LIFS-561 system, where the two emission peaks, at 680 nm and 730 nm, are characteristic of chlorophyll fluorescence emission (CHlF). [26][27][28][29]40 Figures 5 and 6 show the score plot for three PCs, PC1 Â PC2 Â PC3, of PCA analysis using the fluorescence spectra (LIFS-405 and LIFS-561, respectively) of leaves from different Pera sweet orange accessions grafted in Rangpur lemon rootstock.…”
Section: Resultsmentioning
confidence: 99%
“…The first system has a diode laser CUBE Model produced by Coherent with excitation at 405 nm and maximum output power of 50 mW at room temperature, and a high sensitivity mini-spectrometer manufactured by Ocean Optics (USB4000) with spectral range of 194-894 nm. 18,19,25,30 It will be addressed as LIFS-405 from now on. Referred to as LIFS-561, the second system comprises a diode laser COMPASS model, also produced by Coherent, but with emission at 561 nm.…”
Section: Leaf Samplesmentioning
confidence: 99%
See 1 more Smart Citation
“…Today, chlorophyll fluorescence is widely used in research on the correlation with the physiological state of vegetation. Chlorophyll fluorescence detection has achieved good results at the leaf scale and at the canopy scale and has also been used effectively to monitor vegetation water stress [29,30,42,72,73,93,105,106,107,108,109,110,111], ozone stress [66,112,113], nitrogen stress [3,4,54,114,115,116,117,118], pest stress [119,120], GPP [14,15,16,17,18,19,20,21,22,23,121,122,123,124], heat stress [125], and crop productivity [126]. Despite many experiments designed to clarify the relationship between chlorophyll fluorescence and vegetation stress, the internal mechanisms of this relationship remain to be explored.…”
Section: Current Problems and Discussionmentioning
confidence: 99%
“…12 Ainda na temática do Greening, Ranulfi e colaboradores utilizaram espectros de fluorescência na categorização de plantas sadias, sintomáticas e assintomáticas de HBL. 13 A técnica LIFI também apresenta excitação em 405 nm e utiliza uma câmera digital comercial.…”
Section: Lista De Tabelasunclassified