2020
DOI: 10.1007/s10103-020-02963-x
|View full text |Cite
|
Sign up to set email alerts
|

Laser-induced fluorescence diagnosis of stomach tumor

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
3
1
1

Citation Types

0
6
0

Year Published

2021
2021
2024
2024

Publication Types

Select...
7

Relationship

1
6

Authors

Journals

citations
Cited by 7 publications
(6 citation statements)
references
References 21 publications
0
6
0
Order By: Relevance
“…The peak wavelength of the laser (635 nm) was chosen as the best trade-o (i) using only one fluorescence excitation light source; (ii) extending tissue dep (compared to blue light excitation); and (iii) enabling the detection of three d (Ce6, PpIX, and MB). Regarding Ce6, despite its second main absorption pea gion of 660 nm, its molar extinction at 635 nm is still about 5000 cm −1 /M (whic The imaging system has already been tested in clinical settings and has shown that it detects fluorescence in real conditions with sufficient sensitivity [29,30]. In the present work, the experiment was designed to be as close as possible to the picture obtained in real conditions.…”
Section: Bimodal Endoscopic System and Image Acquisition Protocolmentioning
confidence: 94%
See 2 more Smart Citations
“…The peak wavelength of the laser (635 nm) was chosen as the best trade-o (i) using only one fluorescence excitation light source; (ii) extending tissue dep (compared to blue light excitation); and (iii) enabling the detection of three d (Ce6, PpIX, and MB). Regarding Ce6, despite its second main absorption pea gion of 660 nm, its molar extinction at 635 nm is still about 5000 cm −1 /M (whic The imaging system has already been tested in clinical settings and has shown that it detects fluorescence in real conditions with sufficient sensitivity [29,30]. In the present work, the experiment was designed to be as close as possible to the picture obtained in real conditions.…”
Section: Bimodal Endoscopic System and Image Acquisition Protocolmentioning
confidence: 94%
“…A bimodal video system with a rigid endoscope featuring a 45-degree bevel was used for image acquisition. The main technical features of this device, developed by our team, are provided in [29,30]. Briefly, it consists of two cameras (a highly sensitive black-andwhite digital CCD with an optical filter and a color camera), beam splitter, cystoscope, and illuminating devices (WL source, laser).…”
Section: Bimodal Endoscopic System and Image Acquisition Protocolmentioning
confidence: 99%
See 1 more Smart Citation
“…Low power He-Ne lasers have been used clinically to prevent as well as treat skin infections and promote wound healing. However, because the depth for the function of the low-level laser is shallow[ 49 ], causing it have to have less effect on deep tissue, this approach needs to be combined with other physical therapies such as electrical stimulation and HBO therapy if the flap is thick.…”
Section: Phototherapymentioning
confidence: 99%
“…Fluorescent probes have different principles, such as EPR effects (enhanced permeability and retention) and antigen-antibody reactions. To date, fluorescence imaging has exhibited promising advantages in various tumors, such as brain tumors ( 5 ), breast cancer ( 6 ), and gastric cancer ( 7 ).…”
Section: Introductionmentioning
confidence: 99%