1982
DOI: 10.1021/ac00243a019
|View full text |Cite
|
Sign up to set email alerts
|

Laser-induced fluorescence detection for conventional and microcolumn liquid chromatography

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
1
1
1
1

Citation Types

0
39
0

Year Published

1983
1983
2012
2012

Publication Types

Select...
9
1

Relationship

0
10

Authors

Journals

citations
Cited by 124 publications
(39 citation statements)
references
References 15 publications
0
39
0
Order By: Relevance
“…Tsuda and Novotny [89] studied the band-broadening in 50 -195 lm ID columns, reporting better results than they had anticipated, at low retention factors. With the short light path lengths of on-column UV detection, the demands on sample concentrations were high, however, and that focused greater attention on use of the more sensitive fluorescence detector, as demonstrated by Folestad et al [90], Jorgenson and Guthrie [39], and van Berkel et al [91]. Although the practical difficulties of both making and handling extremely small diameter columns are considerable, columns with inner diameters of 10 lm and less were used by Tsuda et al [92], Kreijci et al [93], Folestad and Larsson [94], Simon et al [95], Dohmeier and Jorgenson [96], and Göhlin and Larsson [97].…”
Section: The Fate Of the Open Tubular Column In Lcmentioning
confidence: 99%
“…Tsuda and Novotny [89] studied the band-broadening in 50 -195 lm ID columns, reporting better results than they had anticipated, at low retention factors. With the short light path lengths of on-column UV detection, the demands on sample concentrations were high, however, and that focused greater attention on use of the more sensitive fluorescence detector, as demonstrated by Folestad et al [90], Jorgenson and Guthrie [39], and van Berkel et al [91]. Although the practical difficulties of both making and handling extremely small diameter columns are considerable, columns with inner diameters of 10 lm and less were used by Tsuda et al [92], Kreijci et al [93], Folestad and Larsson [94], Simon et al [95], Dohmeier and Jorgenson [96], and Göhlin and Larsson [97].…”
Section: The Fate Of the Open Tubular Column In Lcmentioning
confidence: 99%
“…For columns of 5 and 10-pm i.d., a laser induced fluorescence detection system [25] consisting of an He-Cd laser (Model 4210 NB from Liconix) or an Argon ion laser (Model 2025 from Spectra Physics) was used. The layout of the optical system has been described previously [26].…”
Section: Equipmentmentioning
confidence: 99%
“…22 They used a 120-.um-diam exit nozzle to produce a very fine jet of liquid at the exit of the column. However, the low volumetric flow rates employed in capillary separations limited the performance of the liquid jet detector.…”
Section: B Fluorescence Detectionmentioning
confidence: 99%