“…Nonetheless, in the interim between nebulisation and movement deep into the lung hygroscopic effects may occur and for this reason gas temperature and humidity values are provided. On the other hand, as demonstrated in Martin et al (2010), because of the high output of the Akita Apixneb vibrating mesh nebulizer, initial droplet evaporation rapidly humidifies the surrounding …”
Section: Data Interpretation and Limitationsmentioning
“…Nonetheless, in the interim between nebulisation and movement deep into the lung hygroscopic effects may occur and for this reason gas temperature and humidity values are provided. On the other hand, as demonstrated in Martin et al (2010), because of the high output of the Akita Apixneb vibrating mesh nebulizer, initial droplet evaporation rapidly humidifies the surrounding …”
Section: Data Interpretation and Limitationsmentioning
“…A detailed review of laser diffractometry as it relates to sizing of medical aerosols can be found in Mitchell et al, (21) whereas more recent publications explore the technique for sizing droplets produced by vibrating mesh nebulizers in particular. (18,22) The apparatus used to supply nebulized aerosol to the laser diffraction system is depicted in Figure 1. The total flow through the measurement region was determined through a vacuum control valve adjusted according to the differential pressure across a venturi tube.…”
“…As shown schematically in Figure 1, the sheath air entered the measurement chamber through two open screw-type valves, but was kept from mixing with the aerosol stream prior to the measurement through the use of a custom designed inlet (Activaero GmbH, Germany) that extended into the chamber just up to the point of intersection with the laser beam, as described previously. (18) For air, the difference between the vacuum flow rate and the supplied gas flow rate determined the sheath air flow rate. For He/O 2 , however, the influence of gas density on the flow-pressure drop relationship of the venturi tube created a complication.…”
“…As such, the influence of He/O 2 on aerosol delivery during NIV should be evaluated for a given combination of delivery device and breathing circuit prior to employing that combination for coadministration of He/O 2 and aerosol therapy. Further, as He/O 2 is known to affect droplet size distributions delivered from jet nebulizers, (14)(15)(16)(17) and, though less so, from vibrating mesh nebulizers, (16,18) these modalities of aerosol delivery may require particular attention.…”
Ventilation with helium-oxygen in place of air-oxygen mixtures can influence both the droplet size distribution and mass of nebulized aerosol delivered through patient breathing circuits. Assessment of these effects on aerosol delivery is important when incorporating helium-oxygen into patient ventilation strategies.
“…À noter que les effets de la densité du gaz propulseur sur le nébuliseur sont variables en fonction du type d'appareil utilisé, point qui doit être gardé à l'esprit lors de l'analyse des études et dans la pratique clinique [58].…”
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.