2010
DOI: 10.1016/j.jaerosci.2010.08.003
|View full text |Cite
|
Sign up to set email alerts
|

Laser diffraction characterization of droplet size distributions produced by vibrating mesh nebulization in air and a helium–oxygen mixture

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
1
1
1

Citation Types

0
8
0
1

Year Published

2011
2011
2021
2021

Publication Types

Select...
6
1

Relationship

0
7

Authors

Journals

citations
Cited by 18 publications
(9 citation statements)
references
References 27 publications
0
8
0
1
Order By: Relevance
“…Nonetheless, in the interim between nebulisation and movement deep into the lung hygroscopic effects may occur and for this reason gas temperature and humidity values are provided. On the other hand, as demonstrated in Martin et al (2010), because of the high output of the Akita Apixneb vibrating mesh nebulizer, initial droplet evaporation rapidly humidifies the surrounding …”
Section: Data Interpretation and Limitationsmentioning
confidence: 99%
“…Nonetheless, in the interim between nebulisation and movement deep into the lung hygroscopic effects may occur and for this reason gas temperature and humidity values are provided. On the other hand, as demonstrated in Martin et al (2010), because of the high output of the Akita Apixneb vibrating mesh nebulizer, initial droplet evaporation rapidly humidifies the surrounding …”
Section: Data Interpretation and Limitationsmentioning
confidence: 99%
“…A detailed review of laser diffractometry as it relates to sizing of medical aerosols can be found in Mitchell et al, (21) whereas more recent publications explore the technique for sizing droplets produced by vibrating mesh nebulizers in particular. (18,22) The apparatus used to supply nebulized aerosol to the laser diffraction system is depicted in Figure 1. The total flow through the measurement region was determined through a vacuum control valve adjusted according to the differential pressure across a venturi tube.…”
Section: Laser Diffraction Measurement Apparatusmentioning
confidence: 99%
“…As shown schematically in Figure 1, the sheath air entered the measurement chamber through two open screw-type valves, but was kept from mixing with the aerosol stream prior to the measurement through the use of a custom designed inlet (Activaero GmbH, Germany) that extended into the chamber just up to the point of intersection with the laser beam, as described previously. (18) For air, the difference between the vacuum flow rate and the supplied gas flow rate determined the sheath air flow rate. For He/O 2 , however, the influence of gas density on the flow-pressure drop relationship of the venturi tube created a complication.…”
Section: Laser Diffraction Measurement Apparatusmentioning
confidence: 99%
See 1 more Smart Citation
“…À noter que les effets de la densité du gaz propulseur sur le nébuliseur sont variables en fonction du type d'appareil utilisé, point qui doit être gardé à l'esprit lors de l'analyse des études et dans la pratique clinique [58].…”
Section: Bronchopneumopathie Chronique Obstructive (Bpco)unclassified