1996
DOI: 10.1039/ja9961100401
|View full text |Cite
|
Sign up to set email alerts
|

Laser ablation–inductively coupled plasma mass spectrometry with a time-of-flight mass analyser

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
1
1
1
1

Citation Types

1
33
0

Year Published

1998
1998
2015
2015

Publication Types

Select...
4
4

Relationship

0
8

Authors

Journals

citations
Cited by 60 publications
(35 citation statements)
references
References 15 publications
1
33
0
Order By: Relevance
“…[120][121][122][123][124][125][126] A detection limit of 10 ppb for lead in a cast-iron standard has been reported from integration of a 0.3 s transient signal generated by a single laser pulse. 120 The opimization of various ICP-TOF-MS parameters for laser-induced aerosols and for the analysis of tin-rich fluid inclusions has been described. 121 The developed method allows the simultaneous detection of 63 isotopes with the DLs within the 1 -100 µg g -1 range for an 80 µm crater diameter.…”
Section: Applications Of Icp-tof-ms Technique In Elemental Analysismentioning
confidence: 99%
See 1 more Smart Citation
“…[120][121][122][123][124][125][126] A detection limit of 10 ppb for lead in a cast-iron standard has been reported from integration of a 0.3 s transient signal generated by a single laser pulse. 120 The opimization of various ICP-TOF-MS parameters for laser-induced aerosols and for the analysis of tin-rich fluid inclusions has been described. 121 The developed method allows the simultaneous detection of 63 isotopes with the DLs within the 1 -100 µg g -1 range for an 80 µm crater diameter.…”
Section: Applications Of Icp-tof-ms Technique In Elemental Analysismentioning
confidence: 99%
“…Exceptional attributes of ICP-TOF-MS, such as high speed of data acquisition, an ability to obtain a full elemental analysis in a time-frame suited to a transient inlet system and significantly better, as compared with widely used quadrupole ICP-MS, the precision of the measurements generate increasing interest in the technique. The ICP-TOF-MS has been successfully coupled to LA, [120][121][122][123][124][125][126] ETV, 127 GC, [128][129][130][131][132] liquid chromatography, 133,134 CE 135,136 and FIA. [137][138][139][140][141] Detailed reviews of the development and analytical performance of TOF-MS combined with ICP ion source have been presented.…”
Section: An Overview Of Analytical Applications Of Tof-ms Analyzersmentioning
confidence: 99%
“…ICPMS instruments with time-of-flight (TOF) analyzers were recently demonstrated with LA sampling. 54 The TOF approach allows the collection of several thousand complete mass spectra per second. Owing to the transient nature of LA, ICPMS with a TOF analyzer is potentially advantageous for multielemental determinations, although to date only limited research has been conducted.…”
Section: Section Title Will Appear Herementioning
confidence: 99%
“…A minimum of 5 to 10 ms dwelltime is necessary for the determination of each mass. Vaporization of micro samples by an electrothermal or laser pulse and ionizations by an ICP generates transient signals with a width of a few hundreds of ms [4]. Since the typical timescale for scanning through the mass range from, e.g.…”
Section: Introductionmentioning
confidence: 99%