Laryngoscope Illuminance in a Tertiary Children’s Hospital

Abstract: At our facility, approximately one-third of incandescent laryngoscopes exhibited substandard light output. On the basis of these findings, our hospital has converted all of its incandescent laryngoscopes to light-emitting diode (LED) devices. Such changes, as well as the institution of a quality-control program including scheduled laryngoscope inspection and battery and bulb replacement for incandescent laryngoscopes, may reduce adverse events associated with poor-quality direct laryngoscopy.

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
2
1

Citation Types

1
15
0
7

Year Published

2015
2015
2019
2019

Publication Types

Select...
6

Relationship

1
5

Authors

Journals

citations
Cited by 6 publications
(23 citation statements)
references
References 18 publications
1
15
0
7
Order By: Relevance
“…11 Briefly, 3 serial measurements were taken for each device at 10-second intervals and averaged to give a final illuminance value for that device. For AC-powered xenon light source laryngoscopes, all source boxes were initially tested using the same light cable, and the unit closest to the group mean was then used for testing all laryngoscopes.…”
Section: Methodsmentioning
confidence: 99%
“…11 Briefly, 3 serial measurements were taken for each device at 10-second intervals and averaged to give a final illuminance value for that device. For AC-powered xenon light source laryngoscopes, all source boxes were initially tested using the same light cable, and the unit closest to the group mean was then used for testing all laryngoscopes.…”
Section: Methodsmentioning
confidence: 99%
“…Cumpre destacar que é essencial a criação de diretrizes de Procedimentos Operacionais Padrão (POPs) para direcionamento das manutenções, sobretudo devido às inúmeras recomendações dos fabricantes e à fragilidade dos equipamentos cirúrgicos, que pode provocar o seu não funcionamento no período de realização de uma cirurgia 6,7 .…”
Section: Discussionunclassified
“…Quanto aos laringoscópios, a avaliação diária é essencial para atender o paciente de forma segura na intubação traqueal e na anestesia. A manutenção dos laringoscópios envolve, sobretudo, qualidade e níveis aceitáveis de luz para o procedimento 6 . Um estudo realizado em Norfolk (Virgínia, Estados Unidos) avaliou a qualidade da iluminação de 691 laringoscópios, dos quais 28% estavam abaixo do padrão preconizado (entre 500 e 867 lux) 6 .…”
Section: Discussionunclassified
See 2 more Smart Citations