2006
DOI: 10.1016/j.ijpvp.2006.02.032
|View full text |Cite
|
Sign up to set email alerts
|

Larson–Miller correlation for the effect of thermal ageing on the yield strength of a cold worked 15Cr–15Ni–Ti modified austenitic stainless steel

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
1
1
1

Citation Types

0
5
0

Year Published

2011
2011
2022
2022

Publication Types

Select...
9

Relationship

1
8

Authors

Journals

citations
Cited by 17 publications
(5 citation statements)
references
References 6 publications
(10 reference statements)
0
5
0
Order By: Relevance
“…It can be seen that they do not provide good fits to experimental data, and as such, are often implemented in a more flexible way. The more practical application of these models provides individual fits at each temperature such that their parameters function, P , change with temperature rather than being tied to an initially derived value [ 47 – 49 ]. This produces substantially better fits but also introduces the unknown dependency of these parameters, and hence constants, to temperature.…”
Section: Resultsmentioning
confidence: 99%
“…It can be seen that they do not provide good fits to experimental data, and as such, are often implemented in a more flexible way. The more practical application of these models provides individual fits at each temperature such that their parameters function, P , change with temperature rather than being tied to an initially derived value [ 47 – 49 ]. This produces substantially better fits but also introduces the unknown dependency of these parameters, and hence constants, to temperature.…”
Section: Resultsmentioning
confidence: 99%
“…This resulted the value of C as 13. The same value of the constant C was used to correlate the tensile properties of D9 alloy in an earlier investigation [17]. Hence, in the present investigation, the value of C as 13 has been taken for the correlation analysis.…”
Section: Resultsmentioning
confidence: 99%
“…The maximum load was fixed at 10 mN and a trapezoidal load function (30 s load to the maximum load value, maintenance for 10 s, and unloading in 30 s) was used. In order to obtain statistically reliable data, for each experimental condition, matrices of 8 × 8 (64) indents were carried out. The nanoindentation measurements were subsequently analyzed using the Oliver and Pharr method [26][27][28].…”
Section: Methodsmentioning
confidence: 99%
“…and is used to obtain a master curve of hardness or yielding as a function of tempering parameters (temperature and duration) [64][65][66]. Thus, the idea of using Eq.…”
Section: 2mentioning
confidence: 99%