2012
DOI: 10.2172/1060676
|View full text |Cite
|
Sign up to set email alerts
|

Large-Scale Spray Releases: Initial Aerosol Test Results

Abstract: Malvern Insitec-S instruments were used to measure the size distribution and volume concentration of the aerosol. The total spray volume was calculated using differential mass and flow measurements. Measure the pressure and flow in the piping. Met: The pressure and flow in the piping were measured and recorded with a data acquisition system. Characterize the viscosity or rheology, particle size distribution, bulk density, and surface tension of each simulant tested. Met: The simulants tested were characterized… Show more

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
1
1

Citation Types

1
34
0

Year Published

2012
2012
2020
2020

Publication Types

Select...
5

Relationship

3
2

Authors

Journals

citations
Cited by 7 publications
(35 citation statements)
references
References 24 publications
(46 reference statements)
1
34
0
Order By: Relevance
“…Initial testing to obtain aerosol release fraction and net generation rates has recently been completed in small-and large-scale test stands, as discussed in this report and in the large-scale aerosol report (Schonewill et al 2012). These tests were conducted with simulants representing the expected WTP process stream properties over a range of orifice sizes, geometries, and line pressures.…”
Section: S6 Discrepancies and Follow-on Testsmentioning
confidence: 99%
See 2 more Smart Citations
“…Initial testing to obtain aerosol release fraction and net generation rates has recently been completed in small-and large-scale test stands, as discussed in this report and in the large-scale aerosol report (Schonewill et al 2012). These tests were conducted with simulants representing the expected WTP process stream properties over a range of orifice sizes, geometries, and line pressures.…”
Section: S6 Discrepancies and Follow-on Testsmentioning
confidence: 99%
“…The comparison is ambiguous because of evidence that the PPC vacuum draw tube affected the Malvern measurements and because the PPC suction rates had not been tested to determine what rate produced the best measurements. For context, the large-scale tests (Sections 8.1.4 and 8.1.5 of Schonewill et al 2012), in which the PPC suction flow rate was adjusted for best results based on testing, gave a closer comparison between PPC and Malvern results. …”
mentioning
confidence: 99%
See 1 more Smart Citation
“…Only the success criteria for the small-scale plugging tests are given in the table. The success criteria for the aerosol tests are not shown in this table and are discussed in Mahoney et al 2012 andSchonewill et al 2012. …”
Section: S2 Results and Performance Against Success Criteriamentioning
confidence: 99%
“…The results of the small-scale aerosol generation tests are included in Mahoney et al (2012). The area of spray generation from large breaches is covered by large-scale testing in Schonewill et al (2012). …”
mentioning
confidence: 99%