2011
DOI: 10.1007/s10967-011-1519-7
|View full text |Cite
|
Sign up to set email alerts
|

Large sample neutron activation analysis of dross for gold and silver

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
3
1
1

Citation Types

0
7
0
1

Year Published

2013
2013
2021
2021

Publication Types

Select...
6
1

Relationship

1
6

Authors

Journals

citations
Cited by 10 publications
(8 citation statements)
references
References 10 publications
0
7
0
1
Order By: Relevance
“…In the framework of metallic mineral survey projects, 10-15 g samples had to be analyzed to circumvent tedious homogenization procedures [52]. In view of a study on metal recovery and accounting, large-sample NAA was used for the quantification of Au and Ag in 50-100 g dross samples refined at the India Government Mint [53]. As such, the difficulties in the dissolution of the refractory material were circumvented.…”
Section: Direct Analysis Of Materials For Which Homogenization Is Inconvenient Difficult or Close To Impossible And/or Too Expensive Due mentioning
confidence: 99%
“…In the framework of metallic mineral survey projects, 10-15 g samples had to be analyzed to circumvent tedious homogenization procedures [52]. In view of a study on metal recovery and accounting, large-sample NAA was used for the quantification of Au and Ag in 50-100 g dross samples refined at the India Government Mint [53]. As such, the difficulties in the dissolution of the refractory material were circumvented.…”
Section: Direct Analysis Of Materials For Which Homogenization Is Inconvenient Difficult or Close To Impossible And/or Too Expensive Due mentioning
confidence: 99%
“…X‐ray fluorescence (XRF) and neutron activation analysis (NAA) have been established as very efficient and versatile analytical techniques for the direct analysis of solids. Determination of gold and silver in dross by large‐sample NAA technique has been reported from our laboratory . However, the NAA technique requires a nuclear reactor.…”
Section: Introductionmentioning
confidence: 97%
“…The internal comparator content can be also found by an independent method. Matrix or major elements are usually selected to implement internal standardization: Ca for compositional characterization of cement samples [31], Fe to measure element contents of meteorites [29], uranium ore [30] and high-purity aluminum-clad samples [32], and Na for large dross sample analysis for Au and Ag content [33]. Sometimes other elements can be used, such as Sc for the elemental analysis of ancient pottery samples [34], Rb to analyze plant leave samples [27], and La for INAA ISM verification by means of Soil-7 CRM [28].…”
Section: Introductionmentioning
confidence: 99%