2016
DOI: 10.1016/j.micromeso.2015.12.023
|View full text |Cite
|
Sign up to set email alerts
|

Lanthanum-impregnated zeolite modified carbon paste electrode for determination of Cadmium (II)

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
2
1

Citation Types

0
5
0

Year Published

2017
2017
2023
2023

Publication Types

Select...
9

Relationship

0
9

Authors

Journals

citations
Cited by 14 publications
(5 citation statements)
references
References 46 publications
0
5
0
Order By: Relevance
“…The electrolyte solution was 0.1 M phosphate buffer (adjusted at pH 4.4 and 6). The two pH values were selected, according to literature data, , in order to find the best working conditions, taking into account that the behavior of −NH 2 -containing silica powders is influenced by the acidity of the buffer solution. pH values above 6.0 can decrease the electrode signal noticeably, as Cd­(II) ions would precipitate as hydroxide sediments .…”
Section: Methodsmentioning
confidence: 99%
“…The electrolyte solution was 0.1 M phosphate buffer (adjusted at pH 4.4 and 6). The two pH values were selected, according to literature data, , in order to find the best working conditions, taking into account that the behavior of −NH 2 -containing silica powders is influenced by the acidity of the buffer solution. pH values above 6.0 can decrease the electrode signal noticeably, as Cd­(II) ions would precipitate as hydroxide sediments .…”
Section: Methodsmentioning
confidence: 99%
“…The presence of La species in the La-mordonite electrode was also studied by X and al. the authors mentioned that enhances the oxidation process and a reproducible anodic and cathodic peak ascribed to Fe(CN)6 3-/Fe(CN)6 4redox couple at the surface of the electrode (0.17/0.30 V vs. SCE) was observed, proving that La species are available for the redox processes [51].…”
Section: Pollutants Degradation By Fenton-like Oxidation With Lafezsm5mentioning
confidence: 92%
“…In the absence of Caf, two redox processes were identified: one recorded at -0.30 vs. SCE and another at 0.56 V vs. SCE. These values are related to the different metal species, the first one probably attributed to the La(0)/La(III) couple while the second one is attributed to Fe(II)/Fe(III) couple [24,41,51].…”
Section: Pollutants Degradation By Fenton-like Oxidation With Lafezsm5mentioning
confidence: 98%
“…32,33 Zeolite has been used in electroanalysis to measure toxic metal ions. [34][35][36] However, to the best of our knowledge, electrochemical determination of cadmium using the antimony lm modied zeolite modied by y ash doped carbon paste electrode has not been reported up to now. Thus, modication of y ash and application to the electrochemical detection of cadmium ions not only provide a supplementary method for the detection of cadmium ions but also provide new possibilities for the utilization of y ash.…”
Section: Introductionmentioning
confidence: 99%