2005
DOI: 10.1016/j.nimb.2005.03.156
|View full text |Cite
|
Sign up to set email alerts
|

Laboratory simulation of cometary X-rays using a high-resolution microcalorimeter

Abstract: X-ray emission following charge exchange has been studied on the University of California Lawrence Livermore National Laboratory electron beam ion traps EBIT-I and EBIT-II using a high-resolution microcalorimeter. The measured spectra include the K-shell emission from hydrogenlike and heliumlike C, N, O, and Ne needed for simulations of cometary x-ray emission. A comparison of the spectra produced in the interaction of O 8+ with N 2 and CH 4 is presented that illustrates the dependence of the observed spectrum… Show more

Help me understand this report
View preprint versions

Search citation statements

Order By: Relevance

Paper Sections

Select...
1
1
1
1

Citation Types

0
5
0

Year Published

2007
2007
2017
2017

Publication Types

Select...
5

Relationship

1
4

Authors

Journals

citations
Cited by 5 publications
(5 citation statements)
references
References 25 publications
(36 reference statements)
0
5
0
Order By: Relevance
“…Another study that we compare our theoretical data to is that of Beiersdorfer et al (2005) who used the same microcalorimeter spectrometer originally designed for the Astro-E mission. In Figure 6, we present theoretical spectra for O 8+ collisions with N 2 at a collision energy of 10 eV/u compared to the EBIT measurements that have an estimated collision energy of ∼10 eV/u.…”
Section: Appendixmentioning
confidence: 99%
“…Another study that we compare our theoretical data to is that of Beiersdorfer et al (2005) who used the same microcalorimeter spectrometer originally designed for the Astro-E mission. In Figure 6, we present theoretical spectra for O 8+ collisions with N 2 at a collision energy of 10 eV/u compared to the EBIT measurements that have an estimated collision energy of ∼10 eV/u.…”
Section: Appendixmentioning
confidence: 99%
“…The striping is due to the survey geometry where great circles on the sky including the ecliptic poles were scanned precessing at ~1° per day. The spectra were measured on an electron beam ion trap at the Lawrence Livermore National Laboratory by Beiersdorfer et al (2005b). Note that Lyman-ε emanating from n = 6 is only seen in (a).…”
Section: Figure 47mentioning
confidence: 99%
“…High-resolution laboratory measurements have now revealed some of the details of the emission near the limit of the Lyman series (Beiersdorfer et al 2003(Beiersdorfer et al , 2005b. Replacing the rather low-resolution solid-state detectors used in the above-mentioned measurements with a microcalorimeter has enabled Beiersdorfer et al to resolve the Lyman lines, as illustrated in Fig.…”
Section: K-shell X-ray Spectramentioning
confidence: 99%
“…This strong enhancement of high-n Lyman emission is a key feature of low-collision-energy CX spectra. H-like CX spectra have also been obtained using EBITs for Xe 54+ + Xe [115,123], Ne 10+ + Ne [126,127], and O 8+ + various molecules [36]; the last two measurements used the XRS microcalorimeter.…”
Section: H-like Spectramentioning
confidence: 99%