2022
DOI: 10.1016/j.molliq.2022.118754
|View full text |Cite
|
Sign up to set email alerts
|

L-menthol-based eutectic solvents: Characterization and application in the removal of drugs from water

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
3
2

Citation Types

5
11
0

Year Published

2022
2022
2024
2024

Publication Types

Select...
6

Relationship

0
6

Authors

Journals

citations
Cited by 25 publications
(17 citation statements)
references
References 75 publications
5
11
0
Order By: Relevance
“…Experimentally determined densities (ρ) of the DESs Men:DA, Thy:DA, and Thy:Men at four, four, and nine different compositions, respectively, in the temperature range 293.15 to 363.15 K are reported in Table . Previously reported density values of these DESs (only at selected compositions) mostly under ambient conditions (at 298.15 K) ,,, are summarized in Table and reveal excellent agreement with our measured values. Irrespective of the temperature, constituents, and the composition, the densities of all the investigated DESs are lower than that of water under ambient conditions.…”
Section: Resultssupporting
confidence: 89%
See 4 more Smart Citations
“…Experimentally determined densities (ρ) of the DESs Men:DA, Thy:DA, and Thy:Men at four, four, and nine different compositions, respectively, in the temperature range 293.15 to 363.15 K are reported in Table . Previously reported density values of these DESs (only at selected compositions) mostly under ambient conditions (at 298.15 K) ,,, are summarized in Table and reveal excellent agreement with our measured values. Irrespective of the temperature, constituents, and the composition, the densities of all the investigated DESs are lower than that of water under ambient conditions.…”
Section: Resultssupporting
confidence: 89%
“…The relative standard uncertainty in η of the solvents for the entire temperature range is estimated to be 0.02 mPa·s. Table , Figure , and Figure summarize the observed values of density and dynamic viscosity of the selected DESs measured by us as well as those available in the literature. ,,, It is important to state here that the values experimentally measured by us were found to be in good agreement with those reported in the literature. The slight disparities in the measurement values may arise due to differences in the water content present or the presence of impurities.…”
Section: Methodssupporting
confidence: 80%
See 3 more Smart Citations