2014
DOI: 10.1016/j.talanta.2014.07.023
|View full text |Cite
|
Sign up to set email alerts
|

l-cysteine protected copper nanoparticles as colorimetric sensor for mercuric ions

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
1
1
1
1

Citation Types

2
36
0

Year Published

2015
2015
2024
2024

Publication Types

Select...
8
2

Relationship

3
7

Authors

Journals

citations
Cited by 118 publications
(43 citation statements)
references
References 53 publications
2
36
0
Order By: Relevance
“…While plasmonic nanosensors are almost exclusively made of gold or silver, LSPR sensing applications of other metal and/or metal oxide nanocomposites, e.g., zinc oxide [78][79][80], aluminium [81][82][83][84][85][86][87] and copper [88][89][90][91][92][93][94][95][96], have also been investigated. However, the non-noble metals are susceptible to corrosion in aqueous environments and oxidation in air, both of which significantly diminish refractive index sensitivity [4].…”
Section: Effect Of Nanoparticle Composition Size and Shape On Plasmomentioning
confidence: 99%
“…While plasmonic nanosensors are almost exclusively made of gold or silver, LSPR sensing applications of other metal and/or metal oxide nanocomposites, e.g., zinc oxide [78][79][80], aluminium [81][82][83][84][85][86][87] and copper [88][89][90][91][92][93][94][95][96], have also been investigated. However, the non-noble metals are susceptible to corrosion in aqueous environments and oxidation in air, both of which significantly diminish refractive index sensitivity [4].…”
Section: Effect Of Nanoparticle Composition Size and Shape On Plasmomentioning
confidence: 99%
“…The pH of the precursor has been varied from 2 to 8 to obtain colloids E 1 to E 7 . Strong basic medium has been avoided to defy the formation of copper oxides [49]. The UV-vis spectral profiles of A C C E P T E D M A N U S C R I P T ACCEPTED MANUSCRIPT 14 CuNPs prepared under different pH are shown in figure 3(b).…”
Section: E) Effect Of Ph Of the Precursor Solutionmentioning
confidence: 99%
“…The corresponding inset plot shows an R 2 value of 0.9951 with LOD of 12 nM and LOQ of 40 nM. The LOD and LOQ values were determined by the methods reported previously [9,24]. Although the electrode was checked for 100-3600 nM nitrite concentration and was giving good results but the former range was producing the higher linearity and thus chosen for better accuracy.…”
Section: Amperometric Calibrationmentioning
confidence: 99%