2019 IEEE 9th International Nanoelectronics Conferences (INEC) 2019
DOI: 10.1109/inec.2019.8853847
|View full text |Cite
|
Sign up to set email alerts
|

Kretschmann based Surface Plasmon Resonance for Sensing in Visible Region

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
5

Citation Types

0
1
0

Year Published

2021
2021
2024
2024

Publication Types

Select...
7

Relationship

0
7

Authors

Journals

citations
Cited by 11 publications
(6 citation statements)
references
References 30 publications
0
1
0
Order By: Relevance
“…The value of the FWHM is approximately 2.81 • , making it applicable in sensor-based setups. Comparing the calculated FWHM to that in works [12,[16][17][18][19][20] demonstrates the high performance of the proposed structure. The figure of merit is equal to 196.07 RIU −1 .…”
Section: Introductionmentioning
confidence: 63%
See 2 more Smart Citations
“…The value of the FWHM is approximately 2.81 • , making it applicable in sensor-based setups. Comparing the calculated FWHM to that in works [12,[16][17][18][19][20] demonstrates the high performance of the proposed structure. The figure of merit is equal to 196.07 RIU −1 .…”
Section: Introductionmentioning
confidence: 63%
“…A 65 nm thick silicon layer separates graphene and gold layers. By adding a WS 2 layer, the sensitivity of the designed sensor is increased to 333.33 • /RIU, surpassing that in references [12,[16][17][18][19][20]. The value of the FWHM is approximately 2.81 • , making it applicable in sensor-based setups.…”
Section: Introductionmentioning
confidence: 95%
See 1 more Smart Citation
“…In general, SPR has been used to detect a variety of targets, including glucose [ 40 42 ], uric acid [ 43 , 44 ], dopamine [ 27 , 45 , 46 ], antibody [ 47 50 ], antigen [ 47 , 51 , 52 ], salmonella [ 53 ], urea [ 43 , 54 56 ], and creatinine [ 28 , 57 , 58 ], in a variety of applications, including material characterization, medical diagnostics, food quality sensors, and drug development. Yu et al described the development of a D-shaped fiber SPR glucose biosensor with a modified MoS2-graphene composite nanostructure that exhibits approximately fourfold increased sensitivity [ 40 ].…”
Section: Introductionmentioning
confidence: 99%
“…As the wave vector of air and light matches by controlling thin film thickness and light incident angle, the resonance will be achieved resulting the excitation of surface plasmon polaritons (SPP) [16,17]. In short, SPR can be produced by using two techniques, namely prism coupling technique [18] and fiber based technique [19]. The main requirement to generate SPR is the presence of noble metal such as gold and silver.…”
Section: Introductionmentioning
confidence: 99%