1987
DOI: 10.1002/maco.19870381207
|View full text |Cite
|
Sign up to set email alerts
|

Korrosionsbeständige metallische Werkstoffe für Rauchgas‐Entschwefelungsanlagen

Abstract: Aufgrund der Verordnung uber Groafeuerungsanlagen werden in der BR Deutschland derzeit in groBem Umfang Rauchgas-Entschwefelungsanlagen (REA) gebaut. Ahnliches gilt fiir eine Reihe anderer Lhder. Dabei kommen vonviegend nit KalWKalkstein-Aufschlammung arbeitende nasse Waschverfahren zur Anwendung. Maagebend fur die korrosive Beanspruchung der mit den Prozehedien in Beriihrung kommenden Werkstoffe sind die von der Art des Brennstoffs abhangigen Bestandteile der Rauchgase und die Verfahrensfiihrung. Bei pH-Werte… Show more

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
1
1

Citation Types

0
2
0
1

Year Published

1989
1989
2008
2008

Publication Types

Select...
5
2

Relationship

0
7

Authors

Journals

citations
Cited by 20 publications
(3 citation statements)
references
References 2 publications
0
2
0
1
Order By: Relevance
“…The passive layer durability was controlled during long term corrosion exposure in the test solution at 353K. No pitting corrosion was observed for high Mo alloys (A1, A2, A3) due to their high pitting resistance equivalent [9][10][11]. Pitting corrosion was observed with the naked eye on the surface of alloy A4 after 280 days of exposure (Plate 1).…”
Section: Resultsmentioning
confidence: 99%
See 1 more Smart Citation
“…The passive layer durability was controlled during long term corrosion exposure in the test solution at 353K. No pitting corrosion was observed for high Mo alloys (A1, A2, A3) due to their high pitting resistance equivalent [9][10][11]. Pitting corrosion was observed with the naked eye on the surface of alloy A4 after 280 days of exposure (Plate 1).…”
Section: Resultsmentioning
confidence: 99%
“…The test solution and the elevated exposure temperature simulated corrosion conditions of absorber upper zones, outlet ducts, reheat mixing zones and stacks in FGD plants. The solution formula was chosen from a number of electrolytes used for laboratory experiments simulating chosen FGD conditions [9][10][11][12]. Polarisation investigations have been carried out using the GAMRY INSTRUMENTS measurement card controlled by an IBM PC computer.…”
Section: Methodsmentioning
confidence: 99%
“…In einigen Verfahren ist zur Reduzierung der im Rauchgas enthaltenen Chloride, Fluoride und Staubteilchen, die alle den EntschwefelungsprozeB storen, ein Vorwascher dem Hauptwascher vorgeschaltet [3,7]. Waschflussigkeiten aus Vorwaschern sind deshalb durch extrem niedrige pH-Werte gekennzeichnet, die teilweise unter 1 absinken konnen [7].…”
unclassified