2020
DOI: 10.21203/rs.3.rs-129121/v1
|View full text |Cite
Preprint
|
Sign up to set email alerts
|

Knock out of Specific Maternal Vitellogenins in Zebrafish (Danio Rerio) Evokes Vital Changes in Egg Proteomic Profiles that resemble the Phenotype of Poor Quality Eggs

Abstract: Background We previously reported the results of CRISPR/Cas9 knock-out (KO) of type-I and type-III vitellogenins (Vtgs) in zebrafish, which provided the first experimental evidence of essentiality and disparate functioning of specific types of Vtg at different times during vertebrate development. However, the lack of knowledge on specific contributions of different types of Vtg to molecular functions related to major developmental processes remained to be investigated. The present study employed liquid ch… Show more

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
1

Citation Types

0
1
0

Year Published

2023
2023
2023
2023

Publication Types

Select...
1

Relationship

0
1

Authors

Journals

citations
Cited by 1 publication
(1 citation statement)
references
References 81 publications
0
1
0
Order By: Relevance
“…Proteins (2 µg) were in-gel digested with 12.5 ng/μL sequencing grade modified trypsin (Promega, Charbonnières-les-Bains, France) after concentration on one band using a 4-12% Bis-Tris precast gel (NuPAGE ™ ) as previously described [15]. The resulting peptide mixtures were injected onto a TimsTOF Pro instrument (Bruker Daltonik GmbH, Bremen, Germany) coupled to a NanoElute HPLC System equipped with on a 75 µm × 250 mm IonOpticks Aurora 2 C18 column (Ion Opticks Pty Ltd, Fitzroy, Australia) and LC-MS/MS data were acquired using the PASEF method as previously described [16].…”
Section: Protein Digestion Mass Spectrometry Acquisition and Protein ...mentioning
confidence: 99%
“…Proteins (2 µg) were in-gel digested with 12.5 ng/μL sequencing grade modified trypsin (Promega, Charbonnières-les-Bains, France) after concentration on one band using a 4-12% Bis-Tris precast gel (NuPAGE ™ ) as previously described [15]. The resulting peptide mixtures were injected onto a TimsTOF Pro instrument (Bruker Daltonik GmbH, Bremen, Germany) coupled to a NanoElute HPLC System equipped with on a 75 µm × 250 mm IonOpticks Aurora 2 C18 column (Ion Opticks Pty Ltd, Fitzroy, Australia) and LC-MS/MS data were acquired using the PASEF method as previously described [16].…”
Section: Protein Digestion Mass Spectrometry Acquisition and Protein ...mentioning
confidence: 99%