2005
DOI: 10.1081/sl-200042305
|View full text |Cite
|
Sign up to set email alerts
|

Kinetic Spectrophotometric Determination of Copper by Flow Injection Analysis in Cationic Micellar Medium

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
3
1

Citation Types

0
4
0

Year Published

2008
2008
2017
2017

Publication Types

Select...
6

Relationship

0
6

Authors

Journals

citations
Cited by 7 publications
(4 citation statements)
references
References 12 publications
0
4
0
Order By: Relevance
“…The current kinetic method is simple and fast, and can be successfully used to determine copper at trace/ultra-trace levels in poor surface waters of humic and fulvic acid. The method has the advantages of low cost, a linear range of 50-fold, reproducibility, accuracy, and, most importantly, low DLs, comparable with the DLs obtained by the existing catalytic kinetic techniques for the determination of trace quantities of Cu(II) present in water samples [16][17][18][19][20][21][22][23][24][25][26][27]30 in Table 5. Furthermore, it has a reasonable reaction temperature and short reaction time compared to the other kinetic methods.…”
Section: Discussionmentioning
confidence: 97%
“…The current kinetic method is simple and fast, and can be successfully used to determine copper at trace/ultra-trace levels in poor surface waters of humic and fulvic acid. The method has the advantages of low cost, a linear range of 50-fold, reproducibility, accuracy, and, most importantly, low DLs, comparable with the DLs obtained by the existing catalytic kinetic techniques for the determination of trace quantities of Cu(II) present in water samples [16][17][18][19][20][21][22][23][24][25][26][27]30 in Table 5. Furthermore, it has a reasonable reaction temperature and short reaction time compared to the other kinetic methods.…”
Section: Discussionmentioning
confidence: 97%
“…There are several examples of micellar effects upon the attack of nucleophile anions on uncharged substrates [23,24]. The enhancing effects of surfactants have been exploited in the application of a number of analytical kinetic methods [25][26][27].…”
Section: Introductionmentioning
confidence: 99%
“…Because of the great importance of hydrazine, its accurate and economical determination is still a challenging research in analytical chemistry. Among several techniques that have been reported for the determination of hydrazine such as spectrophotometry [6], amperometry [7], potentiometry [3], titrimetry [8] and chemiluminescence [9], electrochemical techniques offer the opportunity for portable, economical, sensitive and rapid methodologies.…”
Section: Introductionmentioning
confidence: 99%