1989
DOI: 10.1021/ac00188a012
|View full text |Cite
|
Sign up to set email alerts
|

Kinetic determination of primary and secondary amines using a fluoride-selective electrode and based on their reaction with 1-fluoro-2,4-dinitrobenzene

Abstract: Mazet, M.; Khadirian, R. D.; Hassani. M. A. J . Chim. Phys. Girard, I.; Gonnet, C. 55, 924-928. Yarmchuk, P.; Weinberger, R.; Hirsch, R.; Cline-Love, L. J. J . Chromatogr. 1984. 283, 47-54. Landy, J. S.; Dorsey, J. G. J . Chromatogr. Sei. 1984, 22, 68-70. Dorsey, J. G.; Khaledi. M. G.; Landy. J. S.; Lin, J. J. Chromatogr. 1984, 316, 183-191. Sasaki, T.; Yasuoka, M.; Suzuki, H. Bull. Chem. SOC. Jpn. 1977, 50, 2538-2541. Gunnarsson, G.; Jonsson, B.; Wennerstrom, H. J . Phys. Chem. 1980, 84, 3114-3121. Lindrnan, … Show more

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
1
1

Citation Types

0
9
0

Year Published

1991
1991
2008
2008

Publication Types

Select...
6
1

Relationship

0
7

Authors

Journals

citations
Cited by 20 publications
(9 citation statements)
references
References 61 publications
0
9
0
Order By: Relevance
“…On the other hand, NCS is reduced to NHS (succinimide). 30,31 All experimental parameters affecting the reaction rate of NCS with HZ and PHZ (electrode characteristics, concentration of NCS, pH, etc.) were optimized by "one at a time" studies.…”
Section: Resultsmentioning
confidence: 99%
See 1 more Smart Citation
“…On the other hand, NCS is reduced to NHS (succinimide). 30,31 All experimental parameters affecting the reaction rate of NCS with HZ and PHZ (electrode characteristics, concentration of NCS, pH, etc.) were optimized by "one at a time" studies.…”
Section: Resultsmentioning
confidence: 99%
“…Using the standard analyte solutions, we can construct a calibration graph of (10 ΔE/S − 1) versus concentration (fixed-time method), 30 where ΔE is the potential variation in a selected time interval Δt (usually 90 s) and S is the slope of the chloride electrode response, which is determined periodically by successive additions of micro-amounts of 100 μL of 1.0 × 10 −2 -3.0 M KCl standard solutions in 25.0 mL of water mixed with 2.0 mL of buffer solution. HZ and PHZ standard solutions can be determined simultaneously in the concentration ranges of 0.5 -20.0 and 0.8 -25.0 μg mL −1 , respectively.…”
Section: Methodsmentioning
confidence: 99%
“…[1][2][3][4][5][6][7] For this purpose, 1-fluoro-2,4-dinitrobenzene [1][2][3][4] and Girard's reagent 3,[5][6][7] are widely used. The former reagent can release fluoride by the reaction with amino acids, amines, hydrazines or phenols, so that a fluoride-selective electrode can be used for the determination of these compounds.…”
mentioning
confidence: 99%
“…(1) Thus, the concentration of NAD(P)H can be determined through the detection of NO 2 -. This approach is very useful because many enzyme reactions can be coupled with the formation of the coenzymes.…”
mentioning
confidence: 99%
See 1 more Smart Citation