2008
DOI: 10.1016/j.jct.2007.07.002
|View full text |Cite
|
Sign up to set email alerts
|

Kinematic viscosity and speed of sound in gaseous CO, CO2, SiF4, SF6, C4F8, and NH3 from 220K to 375K and pressures up to 3.4MPa

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
1
1
1

Citation Types

0
35
1

Year Published

2012
2012
2023
2023

Publication Types

Select...
7

Relationship

1
6

Authors

Journals

citations
Cited by 26 publications
(36 citation statements)
references
References 21 publications
0
35
1
Order By: Relevance
“…On the other hand, the data of EstradaAlexanders and Hurly covers a pressure range that is closer to that limit, hence it becomes easier to calculate the acoustic virial coefficients. Furthermore, the data reported by Estrada-Alexanders and Hurly for u(T, p) using the viscometer is less affected by dissipative processes that occur in CO 2 due to vibrational relaxation of the molecules [45]. This happens because the upper limit of the frequency range of these measurements is about 1 kHz, while for the acoustic resonator it is at least five times larger.…”
Section: Determination Of Acoustic and Pvt Virialmentioning
confidence: 71%
See 1 more Smart Citation
“…On the other hand, the data of EstradaAlexanders and Hurly covers a pressure range that is closer to that limit, hence it becomes easier to calculate the acoustic virial coefficients. Furthermore, the data reported by Estrada-Alexanders and Hurly for u(T, p) using the viscometer is less affected by dissipative processes that occur in CO 2 due to vibrational relaxation of the molecules [45]. This happens because the upper limit of the frequency range of these measurements is about 1 kHz, while for the acoustic resonator it is at least five times larger.…”
Section: Determination Of Acoustic and Pvt Virialmentioning
confidence: 71%
“…coefficients of carbon dioxide For the case of carbon dioxide, we combined two sets of speed-of-sound measurements: those made by Estrada-Alexanders and Hurly with a Greenspan viscometer [45] and those reported by EstradaAlexanders and Trusler [26]. We observed that these two sources of information on u(p, T) are compatible in the regions were their samplings overlap.…”
Section: Determination Of Acoustic and Pvt Virialmentioning
confidence: 99%
“…In the case of the secondary data, [12][13][14]21,26,31,34,36,41 show larger overall discrepancies. However, more illustrative are the results shown in the deviation diagram presented in Fig.…”
Section: Regression and Resultsmentioning
confidence: 99%
“…The parameters for this dilute-gas correlation are given in Table 2. The primary data used in the regression were those of Kestin et al, 43 Hoogland et al, 15 Strehlow and Vogel, 37 Hurly et al, 38 Berg, 39,40 and Wilhelm et al 10 As secondary data, selected points from Ueda and Kigoshi, 26 Timrot et al, 13 Abe et al, 31 and Estrada-Alexanders and Hurly 41 were considered. Only low-pressure secondary points outside the temperature range covered by the primary data were used.…”
Section: Dilute-gas Limitmentioning
confidence: 99%
See 1 more Smart Citation