2019
DOI: 10.1177/1352458519845844
|View full text |Cite
|
Sign up to set email alerts
|

Kappa free light chains is a valid tool in the diagnostics of MS: A large multicenter study

Abstract: Objective: To validate kappa free light chain (KFLC) and lambda free light chain (LFLC) indices as a diagnostic biomarker in multiple sclerosis (MS). Methods: We performed a multicenter study including 745 patients from 18 centers (219 controls and 526 clinically isolated syndrome (CIS)/MS patients) with a known oligoclonal IgG band (OCB) status. KFLC and LFLC were measured in paired cerebrospinal fluid (C… Show more

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
5

Citation Types

8
68
0
8

Year Published

2019
2019
2023
2023

Publication Types

Select...
6
1

Relationship

0
7

Authors

Journals

citations
Cited by 66 publications
(84 citation statements)
references
References 36 publications
8
68
0
8
Order By: Relevance
“…Indeed, kappa index values >5.8 were present in one quarter of OCB-negative patients with MS and 98% of OCB-positive MS controls. An additional qualitative analysis, based on literature-derived [5,24] threshold values (5.9 and 6.6), confirmed our data with 24% and 22% of OCB-negative patients with MS, respectively, having kappa index values above these thresholds.…”
Section: Discussionsupporting
confidence: 85%
See 2 more Smart Citations
“…Indeed, kappa index values >5.8 were present in one quarter of OCB-negative patients with MS and 98% of OCB-positive MS controls. An additional qualitative analysis, based on literature-derived [5,24] threshold values (5.9 and 6.6), confirmed our data with 24% and 22% of OCB-negative patients with MS, respectively, having kappa index values above these thresholds.…”
Section: Discussionsupporting
confidence: 85%
“… established a cut‐off value of 5.9 in a study on 438 patients and Leurs et al. calculated a cut‐off value of 6.6 in a very recent multicentre study on 745 patients.…”
Section: Discussionmentioning
confidence: 99%
See 1 more Smart Citation
“…We compared four different methods to assess an intrathecal synthesis of KFLC in order to help standardize this promising biomarker for the diagnosis of MS. Although measurement of KFLC is easy to perform, it has not yet found its way into clinical routine [9,17]. One of the reasons might be the disagreement about the "correct" cut-off for the KFLC index, which is used to determine the intrathecal produced KFLC fraction [9,17].…”
Section: Discussionmentioning
confidence: 99%
“…Although measurement of KFLC is easy to perform, it has not yet found its way into clinical routine [9,17]. One of the reasons might be the disagreement about the "correct" cut-off for the KFLC index, which is used to determine the intrathecal produced KFLC fraction [9,17]. In addition to the inconsistent use of KFLC index cut-off values, a CSF/serum index reflects the non-linear relationship between blood-derived molecules of different size only inaccurate [1].…”
Section: Discussionmentioning
confidence: 99%