2018
DOI: 10.1519/jsc.0000000000001912
|View full text |Cite
|
Sign up to set email alerts
|

Jumping Performance is Preserved but Not Muscle Thickness in Collegiate Volleyball Players After a Taper

Abstract: Bazyler, CD, Mizuguchi, S, Sole, CJ, Suchomel, TJ, Sato, K, Kavanaugh, AA, DeWeese, BH, and Stone, MH. Jumping performance is preserved but not muscle thickness in collegiate volleyball players after a taper. J Strength Cond Res 32(4): 1020-1028, 2018-The purpose of this study was to examine changes in muscle architecture and jumping performance in NCAA division I women's volleyball players throughout a competitive season and in preparation for conference championships. Ten women volleyball players were tested… Show more

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
4
1

Citation Types

0
22
0
1

Year Published

2018
2018
2023
2023

Publication Types

Select...
6
1

Relationship

1
6

Authors

Journals

citations
Cited by 22 publications
(23 citation statements)
references
References 30 publications
0
22
0
1
Order By: Relevance
“…Additional trials were performed if the difference in jump height was greater than 2 cm. Test–retest reliability has been recently reported from our laboratory for JH (ICC = 0.93 to 0.99, CV = 2.08 to 7.32%) and PPa (ICC = 0.95 to 0.98, CV = 2.20% to 2.31%) [ 20 , 21 ].…”
Section: Methodsmentioning
confidence: 96%
“…Additional trials were performed if the difference in jump height was greater than 2 cm. Test–retest reliability has been recently reported from our laboratory for JH (ICC = 0.93 to 0.99, CV = 2.08 to 7.32%) and PPa (ICC = 0.95 to 0.98, CV = 2.20% to 2.31%) [ 20 , 21 ].…”
Section: Methodsmentioning
confidence: 96%
“…A location half the distance between the greater trochanter and lateral epicondyle of the right femur was identified and marked. A distance 5 cm medial to the mid-femur marking was also identified and marked [ 9 , 18 ]. This medial marking was used for the measurement of MT.…”
Section: Methodsmentioning
confidence: 99%
“…A straight-edge was placed along the skin to ensure that the probe remained along the previously established midline. Three images were obtained and saved for subsequent analysis using the software provided within the ultrasonography device [ 10 , 18 ].…”
Section: Methodsmentioning
confidence: 99%
See 1 more Smart Citation
“…Takahashi (2006) A análise da morfologia muscular por meio da ultrassonografia cinesiológica é uma técnica importante para determinar a função e morfologia do sistema estomatognático por ser baseada em medidas precisas em tempo real da largura transversal do músculo (Palinkas et al, 2010). Esta técnica é considerada padrão ouro na visualização de parâmetros musculares e de boa reprodutibilidade, baixo custo, portabilidade e por não ser uma técnica invasiva que venha a oferecer riscos aos indivíduos durante sua execução (Castelo et al, 2006;Wiesinger et al, 2016;Bazyler et al, 2017;Mourtzakis et al, 2017;Wiesinger et al, 2017).…”
Section: Introductionunclassified