2021
DOI: 10.1016/j.fusengdes.2020.112099
|View full text |Cite
|
Sign up to set email alerts
|

Joining tungsten with steel for DEMO: Simultaneous brazing by Cu-Ti amorphous foils and heat treatment

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
1
1
1

Citation Types

0
8
0

Year Published

2021
2021
2024
2024

Publication Types

Select...
7

Relationship

2
5

Authors

Journals

citations
Cited by 12 publications
(8 citation statements)
references
References 23 publications
0
8
0
Order By: Relevance
“…Samples were inserted into the ampoule and a thermocouple was as close as the samples. Previously we carried out thermocycling with cooling down by water [8,11] that was used to make express comparison of joints, but in this work we decided to carry out thermocycling closer to operating conditions. RAFM steel working temperature is limited to 550 • C, so we decided to heat up the joint to 600 • C, as the joints' temperature can be higher.…”
Section: Methodsmentioning
confidence: 99%
See 2 more Smart Citations
“…Samples were inserted into the ampoule and a thermocouple was as close as the samples. Previously we carried out thermocycling with cooling down by water [8,11] that was used to make express comparison of joints, but in this work we decided to carry out thermocycling closer to operating conditions. RAFM steel working temperature is limited to 550 • C, so we decided to heat up the joint to 600 • C, as the joints' temperature can be higher.…”
Section: Methodsmentioning
confidence: 99%
“…Usually, intermediate layers are used to suppress a mismatch of CTE [9]. In DEMO, in order to relieve these stresses, it is proposed to use Nb [10], V [11], Ti [12], Cu [13], and Ta [14].…”
Section: Introductionmentioning
confidence: 99%
See 1 more Smart Citation
“…Our scientific group investigated Cu-based brazing alloys that rapidly solidified into foil. Cu-28/50Ti, Cu-12/20Sn, and Cu-12/25Ge, wt.% [12,26,33,38], and a vanadium interlayer were used to overcome the mismatch in CTE between tungsten and the Rusfer steel. In all cases, Cu-50Ti brazing alloy was used to join W with V, because Cu, Sn, and Ge do not dissolve in W, while Ti has a good solubility in W. Hence, to join V to Rusfer, other brazing alloys were investigated.…”
Section: The Latest Progress Made In Tungsten/steel Brazingmentioning
confidence: 99%
“…Thus, Fe-based and Ti-based brazing alloys with added melting-point depressants (B, Be, Si) could prospectively aid in the joining of tungsten to RAFM steel. Summarizing the review above, only a few joints can endure the stresses calculated in Section 2.3: [15,18,19,33,38,46]. The highest strength relates to the joints brazed by pure copper.…”
Section: Brazingmentioning
confidence: 99%