2018
DOI: 10.1177/1753193418797890
|View full text |Cite
|
Sign up to set email alerts
|

Ivory arthroplasty for trapeziometacarpal osteoarthritis: 10-year follow-up

Abstract: II.

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
3
1

Citation Types

0
31
0

Year Published

2019
2019
2023
2023

Publication Types

Select...
8
1

Relationship

0
9

Authors

Journals

citations
Cited by 42 publications
(33 citation statements)
references
References 25 publications
(33 reference statements)
0
31
0
Order By: Relevance
“…Long-term reviews of De la Caffiniere prostheses (Chakrabarti et al., 1997; Johnston et al., 2012; Sondergaard et al., 1991) showed survival rates ranging from 76% to 82% and loosening up to 40%. The long-term studies of current ball-and-socket prostheses (Apard and Saint Cast, 2009; Cootjans et al., 2017; Martin-Ferrero, 2014; Toffoli and Teissier, 2017; Vissers et al., 2019) report better survival (89%–96%) and lower loosening rates (4%–7%) in these prostheses, but may experience dislocation at a frequency of approximately 5%. These data were expected because De la Caffiniere implants, despite being a ball-and-socket design, have the important drawbacks of being constrained and cemented, while current prostheses are modular, uncemented, and unconstrained.…”
Section: Discussionmentioning
confidence: 99%
See 1 more Smart Citation
“…Long-term reviews of De la Caffiniere prostheses (Chakrabarti et al., 1997; Johnston et al., 2012; Sondergaard et al., 1991) showed survival rates ranging from 76% to 82% and loosening up to 40%. The long-term studies of current ball-and-socket prostheses (Apard and Saint Cast, 2009; Cootjans et al., 2017; Martin-Ferrero, 2014; Toffoli and Teissier, 2017; Vissers et al., 2019) report better survival (89%–96%) and lower loosening rates (4%–7%) in these prostheses, but may experience dislocation at a frequency of approximately 5%. These data were expected because De la Caffiniere implants, despite being a ball-and-socket design, have the important drawbacks of being constrained and cemented, while current prostheses are modular, uncemented, and unconstrained.…”
Section: Discussionmentioning
confidence: 99%
“…Over the past decades, different implants for the CMC joint have been developed, among which the most often used is the ball-and-socket-type implant (Apard and Saint Cast, 2009; Badía and Sambandam, 2006; Brutus and Kinnen, 2004; Chakrabarti et al., 1997; Comtet, 2000; Cootjans et al., 2017; De la Caffiniere and Aucouturier, 1979; Johnston et al., 2012; Martin-Ferrero, 2014; Sondergaard et al., 1991; Toffoli and Teissier, 2017; Vissers et al., 2019). The long-term outcomes are a common concern of surgeons.…”
Section: Introductionmentioning
confidence: 99%
“…Total TMC joint replacement, which is now part of the therapeutic arsenal, is being more widely used. It allows a faster return to traditional habits (activity) and, in the long-term perspective, provides good results as far as pain relief, the recovery of mobility and strength are concerned (Gaisne et al., 2009; Vissers et al., 2019). However, joint replacement may lead to complications, such as dislocation and loosening (Kollig et al., 2017; Ledoux, 1997).…”
Section: Introductionmentioning
confidence: 99%
“…The main drawback of replacement arthroplasty is aseptic cup loosening, cited as the most common reason for implant failure, leading to revision rates of 42%–51% (Hansen and Homilius, 2010; Hernández-Cortés et al., 2012; Kaszap et al., 2012; Klahn et al., 2012; Kollig et al., 2017). However, a number of good to excellent outcomes have also been published (Badia and Sambandam, 2006; Cootjans et al., 2017; Dehl et al., 2017; Krukhaug et al., 2014; Regnard, 2006; Vissers et al., 2019).…”
Section: Introductionmentioning
confidence: 99%