Isoxsuprine in Nonproliferative Diabetic Retinopathy: Effect on Human Retinal Circulation Assessed by Fluorescein Angiography—A Pilot Study

Abstract: The retinal vessel filling time of 10 patients with early nonproliferative diabetic retinography was measured by fluorescein angiography. Initially, the reproducibility of the authors' standardized fluorescein angiography was assessed by control angiograms on two different dates in each patient. Thereafter, prolonged use (six months) of isoxsuprine sustained release (80 mg/day) led to a nearly 50% reduction of the arterial filling time and a nearly 25% reduction of the arteriovenous filling time, whereas no ch… Show more