2005
DOI: 10.1016/j.susc.2005.06.071
|View full text |Cite
|
Sign up to set email alerts
|

Isotope effects in H+(D+) desorption induced by 4a1← O 1s resonant transition of condensed H2O (D2O)

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...

Citation Types

0
6
0

Year Published

2006
2006
2013
2013

Publication Types

Select...
6

Relationship

0
6

Authors

Journals

citations
Cited by 8 publications
(6 citation statements)
references
References 23 publications
0
6
0
Order By: Relevance
“…Recently, we have developed an analyzer that can be used for both EICO analysis and APECS. 8 EICO spectroscopy has been widely applied in studies of ion desorption from condensed molecules on surfaces such as H2O, 13,[15][16][17][18] NH3, 19 CH3CN, 20 C6H6, 21 Si(CH3)4, 22 SiF3CH2CH2Si(CH3)3, 23 CH3CF3, 24 and N2O, 25 We have developed a miniature electron ion coincidence (EICO) analyzer mounted on a conflat flange with an outer diameter of 114 mm. It consists of a cylindrical mirror analyzer (CMA), a time-of-flight ion mass spectrometer (TOF-MS), a commercially available linear motion feedthrough, and a tilt adjustment mechanism.…”
mentioning
confidence: 99%
See 4 more Smart Citations
“…Recently, we have developed an analyzer that can be used for both EICO analysis and APECS. 8 EICO spectroscopy has been widely applied in studies of ion desorption from condensed molecules on surfaces such as H2O, 13,[15][16][17][18] NH3, 19 CH3CN, 20 C6H6, 21 Si(CH3)4, 22 SiF3CH2CH2Si(CH3)3, 23 CH3CF3, 24 and N2O, 25 We have developed a miniature electron ion coincidence (EICO) analyzer mounted on a conflat flange with an outer diameter of 114 mm. It consists of a cylindrical mirror analyzer (CMA), a time-of-flight ion mass spectrometer (TOF-MS), a commercially available linear motion feedthrough, and a tilt adjustment mechanism.…”
mentioning
confidence: 99%
“…These AEY and TIY results agree with those reported in previous studies. 13,[15][16][17][18] Auger-electron photoion coincidence (AEPICO) spectrum Figure 6 shows an Auger-electron photoion coincidence timeof-flight (AEPICO TOF) spectrum of H2O condensed on Si(111) at hv = 532.9 eV corresponding to the 4a1 ← O 1s resonance. The AEPICO TOF spectrum was measured using the EICO analyzer with a multichannel scaler triggered by the electron signal detected with the CMA at an Auger-electron kinetic energy (AeKE) of 516.5 eV (Fig.…”
mentioning
confidence: 99%
See 3 more Smart Citations