2020
DOI: 10.1007/s10967-020-07409-w
|View full text |Cite
|
Sign up to set email alerts
|

Isotope dilution thermal ionization mass spectrometry (ID-TIMS) for determination of concentration of enriched lithium using NaLiBO2+ ions

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2

Citation Types

0
2
0

Year Published

2024
2024
2024
2024

Publication Types

Select...
1

Relationship

1
0

Authors

Journals

citations
Cited by 1 publication
(2 citation statements)
references
References 19 publications
0
2
0
Order By: Relevance
“…This compound is then calibrated using synthetic mixtures containing varying isotope abundance, achieved by gravimetrically mixing calculated proportions of highly enriched isotopes of the element. Then, for a given TIMS methodology, the mass discrimination correction factor K is calculated using the iterative approach. In the 1970s, the National Bureau of Standards (NBS) certified isotopic standards using this method with state-of-the-art instruments available at that period . However, advancements in instrumentation now yield within-run precision lower than certified uncertainties.…”
Section: Introductionmentioning
confidence: 99%
See 1 more Smart Citation
“…This compound is then calibrated using synthetic mixtures containing varying isotope abundance, achieved by gravimetrically mixing calculated proportions of highly enriched isotopes of the element. Then, for a given TIMS methodology, the mass discrimination correction factor K is calculated using the iterative approach. In the 1970s, the National Bureau of Standards (NBS) certified isotopic standards using this method with state-of-the-art instruments available at that period . However, advancements in instrumentation now yield within-run precision lower than certified uncertainties.…”
Section: Introductionmentioning
confidence: 99%
“…However, advancements in instrumentation now yield within-run precision lower than certified uncertainties. In addition, there is better understanding of the uncertainty budget estimation of the adopted analytical methodology prescribed by the JCGM (Joint Committee for Guides in Metrology) GUM (Guide to the Expression of Uncertainty in Measurement)-6:2020, and due to the exhaustion of the prepared isotopic standard, the practice of recertification of the isotopic standards is often being followed. ,− Notably, the total evaporation and ion integration methodology for the isotope ratio of lithium, in lithium isotopic standard (NIST-RM 8545), using NaLiBO 2 + ions has been demonstrated in our laboratory to show close agreement with the recertified value …”
Section: Introductionmentioning
confidence: 99%