1993
DOI: 10.1007/bf00323819
|View full text |Cite
|
Sign up to set email alerts
|

Isotope dilution mass spectrometry of microelectronically relevant heavy metal traces in high-purity cobalt

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
3
1

Citation Types

0
4
0

Year Published

1994
1994
2018
2018

Publication Types

Select...
6
2
1

Relationship

0
9

Authors

Journals

citations
Cited by 19 publications
(4 citation statements)
references
References 29 publications
0
4
0
Order By: Relevance
“…Whole blood samples were mineralised in a HNO 3 -H 2 O 2 mixture, using microwave digestion. Fe was separated from the matrix by anion-exchange chromatography following a solvent/solvent extraction step into diethyl ether (Beer & Heumann, 1993;Kastenmayer et al 1994). All isotopic analyses were performed by negative thermal ionisation -MS according to Walczyk (1997) using a magnetic sector field mass spectrometer (MAT 262; Finnigan MAT) equipped with a multi-collector system for simultaneous ion beam detection.…”
Section: Analysis Of Isotopic Composition Of Blood Samplesmentioning
confidence: 99%
“…Whole blood samples were mineralised in a HNO 3 -H 2 O 2 mixture, using microwave digestion. Fe was separated from the matrix by anion-exchange chromatography following a solvent/solvent extraction step into diethyl ether (Beer & Heumann, 1993;Kastenmayer et al 1994). All isotopic analyses were performed by negative thermal ionisation -MS according to Walczyk (1997) using a magnetic sector field mass spectrometer (MAT 262; Finnigan MAT) equipped with a multi-collector system for simultaneous ion beam detection.…”
Section: Analysis Of Isotopic Composition Of Blood Samplesmentioning
confidence: 99%
“…Each isotopically enriched blood sample was analyzed in duplicate under chemical blank monitoring. Whole blood samples were digested by microwave digestion with a nitric acid-hydrogen peroxide mixture, followed by separation of the sample iron from the matrix by anion-exchange chromatography and a subsequent solvent-solvent extraction step into diethylether (17,19,20). All isotopic analyses were performed by negative thermal ionization mass spectrometry with a magnetic sector field mass spectrometer (Finnigan MAT 262) equipped with a multicollector system for simultaneous ion beam detection (21).…”
Section: Analysis Of the Isotopic Composition Of The Blood Samplesmentioning
confidence: 99%
“…Whole-blood samples were mineralised using an HNO 3 ±H 2 O 2 mixture (5 : 2, v/v) and microwave digestion. Sample Fe was separated from the matrix by anion-exchange chromatography following a solvent± solvent extraction step into diethyl ether (Beer & Heumann, 1993;Kastenmayer et al 1994;Walczyk et al 1997). All isotopic analyses were performed using a magnetic-sectorfield MS (MAT 262; Finnigan MAT) equipped with a multi-collector system for simultaneous ion-beam detection.…”
Section: Iron Isotopic Analysis Of Blood Samplesmentioning
confidence: 99%