2015
DOI: 10.1016/j.fluid.2015.08.003
|View full text |Cite
|
Sign up to set email alerts
|

Isothermal vapor–liquid equilibrium measurements and assessments of 1,1,1,3,3,3-hexafluoropropane+N,N-dimethylformamide/N-methyl-2-pyrrolidone working pairs for absorption power cycles

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
1
1
1

Citation Types

0
8
0

Year Published

2016
2016
2024
2024

Publication Types

Select...
6

Relationship

1
5

Authors

Journals

citations
Cited by 6 publications
(8 citation statements)
references
References 30 publications
0
8
0
Order By: Relevance
“…In order to measure the VLE data of R124-NMP and R124-DMF binary mixtures, the experimental principle given by refs 5, 8, and 10 was adopted in this paper and a VLE measurement system showed in Figure 1 was set. The system composed of some apparatuses which are (1) thermostatic water bath, (2) equilibrium still, (3) temperature controller, (4) refrigerator, (5) vacuum pump, (6) temperature sensors, (7) pressure sensors, (8) refrigerant cylinder, (9) refrigerant storage tank, (10) valves, (11) computer, (12) liquid injector, (13) six-way metering valve, and (14) gas chromatography (GC). The types, operation parameters and measurement accuracy of those apparatuses are listed in Table 1.…”
Section: Vle Measurement Sectionmentioning
confidence: 99%
See 4 more Smart Citations
“…In order to measure the VLE data of R124-NMP and R124-DMF binary mixtures, the experimental principle given by refs 5, 8, and 10 was adopted in this paper and a VLE measurement system showed in Figure 1 was set. The system composed of some apparatuses which are (1) thermostatic water bath, (2) equilibrium still, (3) temperature controller, (4) refrigerator, (5) vacuum pump, (6) temperature sensors, (7) pressure sensors, (8) refrigerant cylinder, (9) refrigerant storage tank, (10) valves, (11) computer, (12) liquid injector, (13) six-way metering valve, and (14) gas chromatography (GC). The types, operation parameters and measurement accuracy of those apparatuses are listed in Table 1.…”
Section: Vle Measurement Sectionmentioning
confidence: 99%
“…28 The five-parameter NRTL model had been successfully employed in correlating the experimental VLE data for binary mixtures, like R161-DMAC or NMP, R236fa-DMF or NMP. 10,11 So, the NRTL model with five parameters was also selected to correlate the VLE data of R124-NMP and R124-DMF from 303.15 to 363.15 K in this paper. The model is expressed as follows (5)…”
Section: Correlation Equationmentioning
confidence: 99%
See 3 more Smart Citations