Proceedings Eighth Annual Applied Power Electronics Conference and Exposition,
DOI: 10.1109/apec.1993.290630
|View full text |Cite
|
Sign up to set email alerts
|

Isolated boost circuit for power factor correction

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
5

Citation Types

0
14
0

Publication Types

Select...
5
3
1

Relationship

0
9

Authors

Journals

citations
Cited by 86 publications
(14 citation statements)
references
References 5 publications
0
14
0
Order By: Relevance
“…Nonisolated multiport converters are usually used in the applications where a low voltage regulation ratio is required [4], [5]. In contrast, in the applications requiring a high voltage regulation ratio, isolated converters which contains a transformer is preferred [6]- [8]. The currently used isolated multiport topologies include the isolated full-bridge converter [6], which uses four controllable power switches for each source, the isolated half-bridge converter [9], which uses two switches for each source, and the isolated single-switch converter [10], which only uses one switch for each source.…”
Section: Introductionmentioning
confidence: 99%
“…Nonisolated multiport converters are usually used in the applications where a low voltage regulation ratio is required [4], [5]. In contrast, in the applications requiring a high voltage regulation ratio, isolated converters which contains a transformer is preferred [6]- [8]. The currently used isolated multiport topologies include the isolated full-bridge converter [6], which uses four controllable power switches for each source, the isolated half-bridge converter [9], which uses two switches for each source, and the isolated single-switch converter [10], which only uses one switch for each source.…”
Section: Introductionmentioning
confidence: 99%
“…Especially, its magnetic components such as the boost inductor and isolation transformer are a primary factor of increasing the size and cost [1]. Whereas, the singlestage PFC converter has a simple structure, and can provide the both isolation and output regulation through single power conversion stage [2]- [3]. However, since its regulation performance and input power factor are worse than those of the two-stage approach, its applications are limited [1].…”
Section: Introductionmentioning
confidence: 99%
“…Some of them have certain limitations. For example, the duty cycle of the converter in [9] should be set larger than 50% even in the start-up mode. The inductor-fed boost converter in [10] has a high voltage stress across the switch when it is turned off, and an additional voltage clamp circuit is required.…”
Section: Introductionmentioning
confidence: 99%
“…A number of isolated converters have been proposed for power factor correction [8]- [9] and high voltage step-up applications [10]- [11]. These topologies include push-pull, isolated boost [8], isolated inductor-fed boost [10]- [11], and isolated buck-boost topologies [12].…”
Section: Introductionmentioning
confidence: 99%