Isoelastic arthroplasty of the metacarpophalangeal joints in rheumatoid arthritis: A preliminary report

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
2
1

Citation Types

0
5
0

Year Published

2000
2000
2021
2021

Publication Types

Select...
5
4

Relationship

0
9

Authors

Journals

citations
Cited by 13 publications
(5 citation statements)
references
References 15 publications
0
5
0
Order By: Relevance
“…4,5 Use of the silicone implant remains the criterion standard, but implant fracture and recurrent instability are common over mediumto long-term follow-up. [1][2][3][4]6,7,17 The SRA was designed and introduced as an alternative to silicone. The aim of this study was to examine our institution's experience with the SRA MCP arthroplasty.…”
Section: Discussionmentioning
confidence: 99%
See 1 more Smart Citation
“…4,5 Use of the silicone implant remains the criterion standard, but implant fracture and recurrent instability are common over mediumto long-term follow-up. [1][2][3][4]6,7,17 The SRA was designed and introduced as an alternative to silicone. The aim of this study was to examine our institution's experience with the SRA MCP arthroplasty.…”
Section: Discussionmentioning
confidence: 99%
“…Silicone metacarpophalangeal (MCP) joint arthroplasty has been used to treat symptomatic rheumatoid arthritis (RA) since the 1960s. [1][2][3][4][5][6][7] Silicone implants have been shown to improve function and pain at the MCP joint in some patients with RA. [8][9][10][11] Despite this, high rates of mechanical failure have been reported in silicone implants after long-term follow-up in patients with RA.…”
Section: Introductionmentioning
confidence: 99%
“…Swanson introduced silicone implants for metacarpophalangeal (MCP) joint arthroplasty in rheumatoid arthritis (Swanson, 1972). Several other implant designs have since been marketed (Adams et al, 1990; Beevers and Seedholm, 1995; Cook et al, 1999; Flatt, 1967; Linscheid, 2000; Lundborg et al, 1993; Möller et al, 1999; Vermeiren et al, 1994). The Swanson implant changed from silicone to high performance (HP) silicone in 1975 and to HP 100-silicone in 1986 to provide better durability.…”
Section: Introductionmentioning
confidence: 99%
“…The two components are snapped together afterwards (hinge joint). The main problem was the migration of the prosthesis so, within a few months postoperatively, the Range Of Motion (ROM) was very poor [21][22][23], which led to its withdrawn from the marketplace. The second design of the constrained Mathys prosthesis (RM prosthesis) with its hinge joint which was used in our case consists of two polyetheretherketone (PEEK) components ( Figure 2B).…”
Section: Discussionmentioning
confidence: 99%