2004
DOI: 10.1051/0004-6361:20031532
|View full text |Cite
|
Sign up to set email alerts
|

ISO deep far-infrared survey in the “Lockman Hole”

Abstract: Abstract. We present the catalogs and source counts for the C 90 (reference wavelength of 90 µm) and C 160 (170 µm) bands, which were extracted from our analysis of an ISO deep far-infrared survey conducted as part of the Japan/UH ISO cosmology project. The total survey area is ∼0.9 deg 2 in two fields within the Lockman Hole. The analysis consists of source extraction using the IRAF DAOPHOT package and simulations carried out by adding artificial sources to the maps to estimate the detection rate, the flux bi… Show more

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
3
2

Citation Types

7
34
2

Year Published

2005
2005
2014
2014

Publication Types

Select...
4
2

Relationship

1
5

Authors

Journals

citations
Cited by 22 publications
(43 citation statements)
references
References 39 publications
7
34
2
Order By: Relevance
“…Figure 12 illustrates both 850-870µm number counts (from Scuba, Laboca, Scuba-2, and ALMA Blain et al, 1999;Scott et al, 2002;Chapman et al, 2002;Cowie et al, 2002;Borys et al, 2003;Webb et al, 2003;Barnard et al, 2004;Coppin et al, 2006;Scott et al, 2006;Knudsen et al, 2008;Beelen et al, 2008;Weiß et al, 2009a;Karim et al, 2013;Casey et al, 2013;Chen et al, 2013a) and 450-500µm (from Scuba, Herschel and Scuba-2 Smail et al, 2002;Oliver et al, 2010;Clements et al, 2010;Béthermin et al, 2012b;Geach et al, 2013;Casey et al, 2013;Chen et al, 2013a). Figure 13 illustrates other infrared and submillimeter number counts in the literature in direct units, from 70µm Béthermin et al, 2010a;Berta et al, 2011), 100µm (Héraudeau et al, 2004;Rodighiero & Franceschini, 2004;Kawara et al, 2004;Berta et al, 2011;Magnelli et al, 2013b), 160µm Kawara et al, 2004;Béthermin et al, 2010a;Berta et al, 2011;Magnelli et al, 2013b), 250µm and 350µm Chen+13 (850) Casey+13 (850 Figure 12: Differential submillimeter number counts at 850µm/870µm (left) and 450-500 µm (right). The 850µm and 870µm number counts come the initial Scuba surveys …”
Section: Number Countsmentioning
confidence: 99%
See 2 more Smart Citations
“…Figure 12 illustrates both 850-870µm number counts (from Scuba, Laboca, Scuba-2, and ALMA Blain et al, 1999;Scott et al, 2002;Chapman et al, 2002;Cowie et al, 2002;Borys et al, 2003;Webb et al, 2003;Barnard et al, 2004;Coppin et al, 2006;Scott et al, 2006;Knudsen et al, 2008;Beelen et al, 2008;Weiß et al, 2009a;Karim et al, 2013;Casey et al, 2013;Chen et al, 2013a) and 450-500µm (from Scuba, Herschel and Scuba-2 Smail et al, 2002;Oliver et al, 2010;Clements et al, 2010;Béthermin et al, 2012b;Geach et al, 2013;Casey et al, 2013;Chen et al, 2013a). Figure 13 illustrates other infrared and submillimeter number counts in the literature in direct units, from 70µm Béthermin et al, 2010a;Berta et al, 2011), 100µm (Héraudeau et al, 2004;Rodighiero & Franceschini, 2004;Kawara et al, 2004;Berta et al, 2011;Magnelli et al, 2013b), 160µm Kawara et al, 2004;Béthermin et al, 2010a;Berta et al, 2011;Magnelli et al, 2013b), 250µm and 350µm Chen+13 (850) Casey+13 (850 Figure 12: Differential submillimeter number counts at 850µm/870µm (left) and 450-500 µm (right). The 850µm and 870µm number counts come the initial Scuba surveys …”
Section: Number Countsmentioning
confidence: 99%
“…The 70µm data is collated from Spitzer MIPS Béthermin et al, 2010a) and Herschel PACS . At 100µm, data are from the ISOPHOT instrument aboard ISO (Héraudeau et al, 2004;Rodighiero & Franceschini, 2004;Kawara et al, 2004) and Herschel PACS Magnelli et al, 2013b). At 160µm-170µm, data are from Spitzer MIPS Béthermin et al, 2010a), ISO ISOPHOT (Kawara et al, 2004), and Herschel PACS Magnelli et al, 2013b).…”
Section: Parametrizing Number Countsmentioning
confidence: 99%
See 1 more Smart Citation
“…36b). The second open diamond in the figure shows the 3 upper limit at 170 m, which is based on the nondetections of the two X-ray sources in the Kawara et al (2004) catalog. For the broad-line AGNs (Fig.…”
Section: Composite Spectral Energy Distributions By Spectral Typementioning
confidence: 99%
“…For the broad-line AGNs (Fig. 36a), we show the 3 upper limits at both 90 and 170 m, which are based on the nondetections of the X-ray-bright broad-line AGNs in the Kawara et al (2004) catalog.…”
Section: Composite Spectral Energy Distributions By Spectral Typementioning
confidence: 99%