2008
DOI: 10.1109/tpwrd.2007.911188
|View full text |Cite
|
Sign up to set email alerts
|

Islanding Detection Assessment of Multi-Inverter Systems With Active Frequency Drifting Methods

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
3
1

Citation Types

0
74
0

Year Published

2008
2008
2019
2019

Publication Types

Select...
6
3

Relationship

0
9

Authors

Journals

citations
Cited by 141 publications
(74 citation statements)
references
References 9 publications
0
74
0
Order By: Relevance
“…In view of this shortcoming of SFS method, this paper presents a new multi grid-connected inverters islanding detection method which is based on phase locked loop (PLL). The proposed method is a composite islanding detection method which combines SFS and Sandia Voltage Shift (SVS) method, and the simulation results verify the effectiveness of the proposed method [3] .…”
Section: Introductionmentioning
confidence: 81%
“…In view of this shortcoming of SFS method, this paper presents a new multi grid-connected inverters islanding detection method which is based on phase locked loop (PLL). The proposed method is a composite islanding detection method which combines SFS and Sandia Voltage Shift (SVS) method, and the simulation results verify the effectiveness of the proposed method [3] .…”
Section: Introductionmentioning
confidence: 81%
“…In addition, this information is used to generate the PV inverter controller command, such as the anti-islanding function and the Active Frequency Drift (AFD) method [10][11][12]14]. This section discusses both the conventional PLL technique and the proposed one to calculate the line frequency.…”
Section: The Line Frequency Measurement Techniques From the Digital Pllmentioning
confidence: 99%
“…To obtain grid synchronization between the grid voltage and the inverter output current, it is very important to obtain grid voltage information, such as the phase, frequency, and magnitude [3][4][5][6][7][8][9]. The frequency measurement, used in the PV inverter controller, is especially important, since it plays a key role in the inverter current command, such as the anti-islanding function [10][11][12][13][14][15].…”
Section: Introductionmentioning
confidence: 99%
“…However, the advent of rapidly growing photovoltaic systems makes some problems to the stability and the power quality in the adjacent utility. Especially, as shown in Fig 1, the most issued problem is islanding phenomenon of grid-connected inverter which is defined as an independent power generation while the utility is disconnected [2,3]. Islanding causes a number of undesirable effects like safety hazard to utility service personnel and equipment malfunction [4].…”
Section: Introductionmentioning
confidence: 99%