Is there a role for mechanical valve prostheses in pulmonary valve replacement late after tetralogy of Fallot repair?: Table 1:

Abstract: A best evidence topic in cardiac surgery was written according to a structured protocol. The question addressed was: What is the role of mechanical valve prostheses in pulmonary valve replacement late after tetralogy of Fallot (TOF) repair? Altogether more than 30 papers were found using the reported search, of which 9 represented the best evidence to answer the clinical question. In addition to this, two papers were found by searching the reference lists of the relevant papers. The authors, journal, date and … Show more

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
1
1

Citation Types

0
7
0

Year Published

2015
2015
2019
2019

Publication Types

Select...
9

Relationship

0
9

Authors

Journals

citations
Cited by 14 publications
(9 citation statements)
references
References 12 publications
0
7
0
Order By: Relevance
“…[36,42] Our choice for a biological valve was in agreement with the vast majority of the reported studies, where tissue valves currently form the mainstay of the surgical treatment for patients with PV regurgitation. [3,3441,4348] Despite the numerous biological valves available for implantation in PV position, the optimal valve choice remains unknown, partly because long-term outcomes are deficient owing to structural valve deterioration necessitating further treatment.…”
Section: Discussionmentioning
confidence: 61%
“…[36,42] Our choice for a biological valve was in agreement with the vast majority of the reported studies, where tissue valves currently form the mainstay of the surgical treatment for patients with PV regurgitation. [3,3441,4348] Despite the numerous biological valves available for implantation in PV position, the optimal valve choice remains unknown, partly because long-term outcomes are deficient owing to structural valve deterioration necessitating further treatment.…”
Section: Discussionmentioning
confidence: 61%
“…A few centres prefer mechanical prostheses in this context and have had acceptable results. However, such valves are limited by the need for life-long anticoagulation, moreover, valve thrombosis seems to be a frequent event [11,12]. Multiple xenograft prostheses and homografts have been tested and are being implanted via several access routes.…”
Section: Discussionmentioning
confidence: 99%
“…Regarding the choice of the most suitable valve to implant in PV position, the first choice is not for a mechanical prosthesis, despite the proven longevity, because of the risks of thromboembolic phenomena and the requirement for life-long anticoagulation ( 41 , 48 ), with tissue valves considered as the first choice for PV implantation ( 2 , 39 49 ). Despite the various models of biological valves available for implantation in PV position, the optimal valve choice remains unknown, partly because long-term out-comes are deficient owing to structural valve deterioration necessitating further treatment ( 48 ).…”
Section: Choice Of the Most Suitable Valve For Surgical Implantationmentioning