2009
DOI: 10.1016/j.iccn.2009.09.002
|View full text |Cite
|
Sign up to set email alerts
|

Is nurse-managed blood glucose control in critical care as safe and effective as the traditional sliding scale method?

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
1
1
1

Citation Types

0
7
0
3

Year Published

2010
2010
2018
2018

Publication Types

Select...
7

Relationship

0
7

Authors

Journals

citations
Cited by 10 publications
(10 citation statements)
references
References 40 publications
0
7
0
3
Order By: Relevance
“…20,29 In addition, despite having a similar study protocol, different centers in other clinical trials had different routines for sampling and analysis of blood glucose levels 10,17,30,31 or considered capillary and arterial blood samples to be interchangeable for purposes of analysis. 12,13,20,21,31,32 Our study addresses this gap in the literature by comparing blood glucose determinations on the basis of the type of sample analyzed. Differences between the 2 groups were found only when we included arterial samples in the analysis (as in the previous studies).…”
Section: Resultsmentioning
confidence: 99%
See 2 more Smart Citations
“…20,29 In addition, despite having a similar study protocol, different centers in other clinical trials had different routines for sampling and analysis of blood glucose levels 10,17,30,31 or considered capillary and arterial blood samples to be interchangeable for purposes of analysis. 12,13,20,21,31,32 Our study addresses this gap in the literature by comparing blood glucose determinations on the basis of the type of sample analyzed. Differences between the 2 groups were found only when we included arterial samples in the analysis (as in the previous studies).…”
Section: Resultsmentioning
confidence: 99%
“…33,[35][36][37][38] Bedside glucometer readings in critically ill patients result in overestimates of blood glucose level [39][40][41][42] and lack precision 2,18,32,34,43 for a variety of reasons: fluid accumulation in the fingertips, poor peripheral perfusion due to shock or administration of vasopressors, anemia, sample volume insufficient for analysis, or sampling method used. 20 In addition, glucometers must be calibrated frequently, but such calibration capillary samples from patients receiving intravenous insulin therapy and the third in a capillary sample from a patient receiving subcutaneous insulin therapy.…”
Section: Resultsmentioning
confidence: 99%
See 1 more Smart Citation
“…Diese Form des Typ-1-Diabetes ist mit hoher Penetranz vererbbar, tritt sehr selten und überwiegend bei Patienten mit asiatischem oder afrikanischem Hintergrund auf [Imagawa 2000, EK III]. 1…”
Section: Idiopathischer Typ-1-diabetesunclassified
“…[3][4][5][6] Although the pOC glucometer is of particular concern in patients with anemia, [7][8][9] it has been used in numerous studies. 10 In critically ill patients, pressure-monitoring systems connected to indwelling arterial catheters also allow repeated extraction of blood samples. 11 Although this avoids the discomfort associated with fingersticks, it is not exempt from complications 12 and the daily loss of 40 to 70 mL of blood.…”
Section: Intervention Groupmentioning
confidence: 99%