2012
DOI: 10.1016/j.saa.2011.09.068
|View full text |Cite
|
Sign up to set email alerts
|

Iron(III) oxidized nucleophilic coupling of catechol with o-tolidine/p-toluidine followed by 1,10-phenanthroline as new and sensitivity improved spectrophotometric methods for iron present in chemicals, pharmaceutical, edible green leaves, nuts and lake water samples

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
1
1

Citation Types

0
7
0

Year Published

2016
2016
2024
2024

Publication Types

Select...
8

Relationship

0
8

Authors

Journals

citations
Cited by 15 publications
(7 citation statements)
references
References 13 publications
0
7
0
Order By: Relevance
“…Then, at 30 min and 1, 2, 3, 4 and 5 h after gavage (about 400 μL corresponding to 5 mg/kg of iron-containing SRM, FITC-labeled SRM or FP), samples were analyzed for Fe 3+ or fluorescence. Each blood sample was immediately centrifuged (2040× g , 20 min, 4 °C) and the serum separated (150 μL) and analyzed for Fe 3+ , as previously described [ 22 ].…”
Section: Methodsmentioning
confidence: 99%
See 1 more Smart Citation
“…Then, at 30 min and 1, 2, 3, 4 and 5 h after gavage (about 400 μL corresponding to 5 mg/kg of iron-containing SRM, FITC-labeled SRM or FP), samples were analyzed for Fe 3+ or fluorescence. Each blood sample was immediately centrifuged (2040× g , 20 min, 4 °C) and the serum separated (150 μL) and analyzed for Fe 3+ , as previously described [ 22 ].…”
Section: Methodsmentioning
confidence: 99%
“…The area under the curve (AUC) of Fe 3+ or FITC-labeled SRM concentration in the blood versus time and over the level of 238 µg/dL, which corresponds to the mean basal Fe 3+ concentration found in rats at time 0 before administration of the formulations under study, was calculated by the linear trapezoidal rule between time 0 and 5 h. After completion of the bioavailability study, animals were sacrificed and liver, spleen and bone marrow were withdrawn and homogenized for 10 min at 8000 rpm with a PBS made to pH 3 [ 23 ]. The homogenate was centrifuged for 5 min at 10,000 rpm and the supernatant analyzed for Fe 3+ content [ 22 ].…”
Section: Methodsmentioning
confidence: 99%
“…In order to evaluate the accuracy of this uorescence quenching method, a standard method of phenanthroline spectrophotometry was also carried out for ref. 52. Fig.…”
Section: Detection Of Metal Ions In Acidic Environmentmentioning
confidence: 99%
“…The study of Fe 3+ release in simulated intestinal fluid was not attempted, as the ferric ion is insoluble at the relevant pH. The withdrawn samples of receiving phase were analyzed spectrophotometrically for Fe 3+ (Shyla et al, 2012) after centrifugation at 14,000 rpm for 10 min. Blank runs showed the absence of significant interference with the spectrophotometric measurements.…”
Section: Fe 3+ Release Studiesmentioning
confidence: 99%