2013
DOI: 10.1016/j.matchemphys.2012.12.079
|View full text |Cite
|
Sign up to set email alerts
|

Iron doped carbon aerogel – New electrode material for electrocatalytic reduction of H2O2

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
3

Citation Types

1
33
1

Year Published

2015
2015
2020
2020

Publication Types

Select...
6
1

Relationship

1
6

Authors

Journals

citations
Cited by 31 publications
(35 citation statements)
references
References 50 publications
1
33
1
Order By: Relevance
“…This result indicates that the redox couple in rGO-Fe 2 O 3 -GCE shows quasireversible behavior in an aqueous medium. The E 0 ' value found for rGO-Fe 2 O 3 -GCE (-0.39 V vs. SCE) is smaller than -0.210 V (vs. Ag/AgCl) reported for carbon paste electrode modified with Fe doped mesoporous carbon aerogel[46].The effect of pH and buffer solution on the electrochemical behavior of rGO-Fe 2 O 3 on GCE was investigated over the range of pH 2-9 with PBS and the results are illustrated in As the results show the peak currents did not change with increasing the solution pH in PBS 0.01 mol L -1 , the ammonia buffer (pH=9.0) shows an enhancement in redox peak currents clearly. Therefore, the ammonia buffer solution (pH 9.0) was chosen as the optimum working buffer solution for subsequent measurements.…”
contrasting
confidence: 59%
See 1 more Smart Citation
“…This result indicates that the redox couple in rGO-Fe 2 O 3 -GCE shows quasireversible behavior in an aqueous medium. The E 0 ' value found for rGO-Fe 2 O 3 -GCE (-0.39 V vs. SCE) is smaller than -0.210 V (vs. Ag/AgCl) reported for carbon paste electrode modified with Fe doped mesoporous carbon aerogel[46].The effect of pH and buffer solution on the electrochemical behavior of rGO-Fe 2 O 3 on GCE was investigated over the range of pH 2-9 with PBS and the results are illustrated in As the results show the peak currents did not change with increasing the solution pH in PBS 0.01 mol L -1 , the ammonia buffer (pH=9.0) shows an enhancement in redox peak currents clearly. Therefore, the ammonia buffer solution (pH 9.0) was chosen as the optimum working buffer solution for subsequent measurements.…”
contrasting
confidence: 59%
“…compare some of the analytical characteristics from this work and those previously enzymic and nonenzymic reported in the literature[21,25,[44][45][46][47][48][49][50][51][52][53] for H 2 O 2 detection. The detection limits and linear calibration range of the proposed sensor are comparable with those provided by other modified carbon electrodes.…”
mentioning
confidence: 98%
“…There are three main methods of drying organic gels: drying with supercritical CO 2 [5,6] creating gels named aerogels, drying at ambient temperature [7][8][9][10],which gives xerogels or by freeze drying [11]cyrogels. During carbonisation, organic gels are heated from room temperature to the required pyrolysis temperature, generally 600-1050°C [12][13][14][15].…”
Section: Introductionmentioning
confidence: 99%
“…Continuing our previous research work in the field of "green nanomaterials" that can be applied in the development of electrochemical sensors [13,36], in this work the interest was focused on the obtaining of a new modified glassy carbon (GC) electrode, based on Bi nanoparticles incorporated in carbon xerogel. Thus, a sample of homemade carbon xerogel was impregnated with Bi nanoparticles and the obtained new material (Bi-CX) was immobilized in a film of Chi deposited on the surface of a GC electrode.…”
Section: Introductionmentioning
confidence: 99%