2008
DOI: 10.1063/1.2979327
|View full text |Cite
|
Sign up to set email alerts
|

Ionoluminescent response of several phosphor screens to keV ions of different masses

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
1
1
1

Citation Types

0
15
0

Year Published

2008
2008
2023
2023

Publication Types

Select...
7

Relationship

3
4

Authors

Journals

citations
Cited by 19 publications
(15 citation statements)
references
References 23 publications
(27 reference statements)
0
15
0
Order By: Relevance
“…9, it has undergone some modifications since then. 9, it has undergone some modifications since then.…”
Section: Methodsmentioning
confidence: 99%
See 1 more Smart Citation
“…9, it has undergone some modifications since then. 9, it has undergone some modifications since then.…”
Section: Methodsmentioning
confidence: 99%
“…Inc., Font Collins, CO͒. 9. Hence, some corrections, as determined by modeling, are needed when estimating beam currents for H + and He + ions.…”
Section: Methodsmentioning
confidence: 99%
“…It allows particles with pitch angles from approximately 20° to 80° to be detected. The phosphor powder screen used is YAP:Ce (Yttrium Aluminium Perovskite doped with cerium, decay time = 27 ns), the screen was prepared in‐house using a sedimentation method to deposit a uniform layer on a 25.4 mm diameter stainless steel plate . This phosphor was chosen because of its good sensitivity and linearity in the energy range of interest for ion‐induced luminescence.…”
Section: Experiments and Lp Set‐upmentioning
confidence: 99%
“…A uniform screen, deposited on a 25 mm diameter stainless steel plate, was prepared using a sedimentation method, explained in more detail in Ref. 12, to obtain a screen density of approximately 17.59 mg cm −2 . The luminescent centers are Tb +3 ions uniformly distributed in the Y 2 O 2 S host lattice.…”
Section: Luminescence Screenmentioning
confidence: 99%
“…To help calibrate the TJ-II measurements, a benchtop setup was developed in parallel to perform basic studies on the response of the phosphor screen in the ion energy range of interest ͑E Յ 35 keV͒. 12 In the past, the efficiency of phosphor screens to vacuum ultraviolet radiation, x rays and electrons has been studied extensively, but the response to ions in the energy range of interest for a FILD in fusion plasmas was unknown. This limitation has constrained the use of this type of detector to applications that did not require knowledge of the screen's ionoluminescent response with energy, for instance, the correlation of fast ions escaping with MHD plasma activity 3,9 or comparative measurements of ion impact position with ion energy.…”
Section: Introductionmentioning
confidence: 99%