2009
DOI: 10.1161/circulationaha.108.191650
|View full text |Cite
|
Sign up to set email alerts
|

Ionizing Radiation in Cardiac Imaging

Abstract: A preliminary report on medical radiation exposures to the US population based on publicly available sources of data estimated that the collective dose received from medical uses of radiation has increased by Ͼ700% between 1980 and 2006. 1 Computed tomography (CT) has had an annual growth rate of Ͼ10% per year and accounted for Ϸ50% of the collective dose in 2006. Approximately 65% of the collective CT dose is from studies of chest, abdomen, and pelvis. In 2006, cardiac CT accounted for 1.5% of the collective … Show more

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
1
1
1

Citation Types

2
147
0
8

Year Published

2009
2009
2016
2016

Publication Types

Select...
9

Relationship

1
8

Authors

Journals

citations
Cited by 459 publications
(157 citation statements)
references
References 38 publications
2
147
0
8
Order By: Relevance
“…19 The effective dose for diagnostic cardiac catheterization was set at 7mSv for the base analysis, but was varied down to 5mSv for the sensitivity analysis. 20,21 Imaging/testing costs were computed as a combination of professional and technical fees as reported in table 3. For the purpose of cost comparisons, we refer to these costs as imaging costs even though the stress ECG study does not include …”
Section: Methodsmentioning
confidence: 99%
“…19 The effective dose for diagnostic cardiac catheterization was set at 7mSv for the base analysis, but was varied down to 5mSv for the sensitivity analysis. 20,21 Imaging/testing costs were computed as a combination of professional and technical fees as reported in table 3. For the purpose of cost comparisons, we refer to these costs as imaging costs even though the stress ECG study does not include …”
Section: Methodsmentioning
confidence: 99%
“…CCT requires the use of nephrotoxic contrast as well as significant exposure to radiation. Use of prospective triggering as a dose sparing technique is more commonly employed today, which reduces effective radiation doses by 80%, [45] though this does not permit assessment of ejection fraction and wall motion. On the other hand, most of the etiologies related to SCD/VT are still assessable with prospective imaging, as it still allows visualization of the myocardium, chamber size and CAD.…”
Section: Resultsmentioning
confidence: 99%
“…The ECG synchronization protocol can be prospective sequential or retrospective helical. Considering the 64-row devices currently available, while the amount of radiation of one retrospective acquisition with dose modulation is around 9.0 mSv, the effective dose of a prospective acquisition is around 3.0 mSv 26 .…”
Section: Coronary Computed Tomographic Angiography the Testmentioning
confidence: 99%