2020
DOI: 10.1016/j.heliyon.2020.e04613
|View full text |Cite
|
Sign up to set email alerts
|

Ionisable substances chromatography: A new approach for the determination of Ketoprofen, Etoricoxib, and Diclofenac sodium in pharmaceuticals using ion – pair HPLC

Abstract: An ion-pair HPLC method was developed and validated to analyze three of non-steroidal anti-inflammatory drugs (Ketoprofen, Etoricoxib, and Diclofenac sodium) in their pure and pharmaceuticals based on their ionisable characteristics. Cetyltrimethylammonium bromide (Cetrimide) was used as an ion pair reagent since it had not been used before for this purpose. Chromatographic analysis was accomplished using the C18 (250 × 4.6 mm, 5μm) column. Mobile phase consisted of a mixture of 50% Cetrimide M a… Show more

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
3
1

Citation Types

0
8
0

Year Published

2021
2021
2024
2024

Publication Types

Select...
8

Relationship

0
8

Authors

Journals

citations
Cited by 21 publications
(12 citation statements)
references
References 43 publications
0
8
0
Order By: Relevance
“…The full scan spectrum was between 190 and 800 nm. Ketoprofen and aspirin were detected at 254 and 229 nm (Andraws and Trefi, 2020;Massimi et al, 2015), respectively. The LC-20AD mobile phase flow was carried out at a ratio of 20:80 (acetonitrile/water) and 0.5% CH 2 O 2 .…”
Section: Testing and Measurements For Pharmaceuticals Removalmentioning
confidence: 99%
“…The full scan spectrum was between 190 and 800 nm. Ketoprofen and aspirin were detected at 254 and 229 nm (Andraws and Trefi, 2020;Massimi et al, 2015), respectively. The LC-20AD mobile phase flow was carried out at a ratio of 20:80 (acetonitrile/water) and 0.5% CH 2 O 2 .…”
Section: Testing and Measurements For Pharmaceuticals Removalmentioning
confidence: 99%
“…Many analytical HPLC methods have been recorded for the KET analysis of its formulations and enantiomers. [45][46][47][48][49][50][51][52] Omeprazole…”
Section: Introductionmentioning
confidence: 99%
“…CE is included in the European Pharmacopeia where a titration method is described as an assay [10], while this technique can also be found in the literature with even better accuracy and precision data [11]. Regarding High-Performance Liquid Chromatography (HPLC), a series of publications [12][13][14][15] refer to the role of CE as an ion-pairing agent for the analysis of negatively charged ions, but none for its single quantification. On the contrary, an HPLC method for the determination of CHG is described in both the European Pharmacopeia [10] and the USP [16].…”
Section: Introductionmentioning
confidence: 99%