1980
DOI: 10.1515/zna-1980-0121
|View full text |Cite
|
Sign up to set email alerts
|

Ion-Solvent and Solvent-Solvent Interactions. X-ray Study of Aqueous Alkali Chloride Solutions

Abstract: The first neighbour model, FNM, used frequently for the description of hydration has been modified by dropping the assumption that the structure of the "free" solvent is identical with that of the pure solvent. The modified model, FNM2, reproduces the experimental X-ray structure functions of alkali chloride solutions quite well and enables the study of perturbed solvent-solvent interactions. The refined structural parameters reasonably indicate the dependence of the hydration of the alkali cations on their ra… Show more

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
1
1
1
1

Citation Types

7
43
0

Year Published

1982
1982
2024
2024

Publication Types

Select...
8
1

Relationship

1
8

Authors

Journals

citations
Cited by 92 publications
(50 citation statements)
references
References 0 publications
7
43
0
Order By: Relevance
“…The RDF for the Cl − ion and oxygens of water shows a first peak at ∼3.2Å, which agrees with the experimental Cl − -H 2 O bond length obtained by X-ray and neutron diffraction measurements. 48,49 The first peak has a distribution range from 2.9Å to ∼ 4.0Å. The RDF for the ion and hydrogens of water contains a nearest-neighbor peak near 2.3Å.…”
Section: A Local Hydration Structure In Amoeba Simulationsmentioning
confidence: 99%
“…The RDF for the Cl − ion and oxygens of water shows a first peak at ∼3.2Å, which agrees with the experimental Cl − -H 2 O bond length obtained by X-ray and neutron diffraction measurements. 48,49 The first peak has a distribution range from 2.9Å to ∼ 4.0Å. The RDF for the ion and hydrogens of water contains a nearest-neighbor peak near 2.3Å.…”
Section: A Local Hydration Structure In Amoeba Simulationsmentioning
confidence: 99%
“…The total X-ray structure function I (s) is the weighted sum of the partial site-site structure functions [14]:…”
Section: X-ray Structure Functionmentioning
confidence: 99%
“…This gave a total of 40 000 to 240 000 counts per point. The method of measurement and data treatment were as previously reported, 26 including corrections for background, polarization, absorption, subtraction of the scattering pattern of the empty cell, and conversion of the corrected intensities into absolute units. Since the samples were of high purity and some of them very concentrated, the material of the polymer windows was ca.…”
Section: X-ray Diffraction Measurementsmentioning
confidence: 99%