Clinical Chemistry 1989
DOI: 10.1007/978-1-4613-0753-2_25
|View full text |Cite
|
Sign up to set email alerts
|

Ion Selective Electrodes (ISE’s) in Clinical Chemistry

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
4
1

Citation Types

0
5
0

Year Published

2002
2002
2010
2010

Publication Types

Select...
4
1

Relationship

0
5

Authors

Journals

citations
Cited by 5 publications
(5 citation statements)
references
References 19 publications
0
5
0
Order By: Relevance
“…tridodecylamine have been reported (2) . However, the use of plasticiser in PVC membrane based electrodes were later found to be the main cause of thrombocity when used as implantable sensors (3,4) . Many polymer membranes that require less plasticisers compared with PVC were studied as sensing membrane for pH, e.g.…”
Section: Introductionmentioning
confidence: 99%
“…tridodecylamine have been reported (2) . However, the use of plasticiser in PVC membrane based electrodes were later found to be the main cause of thrombocity when used as implantable sensors (3,4) . Many polymer membranes that require less plasticisers compared with PVC were studied as sensing membrane for pH, e.g.…”
Section: Introductionmentioning
confidence: 99%
“…With this greater understanding of how anions can affect key biological processes, research in the field of anion supramolecular chemistry -anion binding and remediation utilizing noncovalent interactions [10,11] -has seen exponential growth in the last 20 years. These activities have led to applications in ion selective electrodes [12][13][14], which can be used for measuring chloride and phosphate concentrations in the human body, as well as to the design of selective receptors for use in environmental anion remediation and liquid-liquid extractions [15,16]. At the foundation of these advances in anion receptor chemistry lies the application of new synthetic methodologies to allow for the creation of these novel receptors.…”
Section: Motivationmentioning
confidence: 99%
“…Over the past decades, ion-selective electrode based potentiometry has become a well-established electro analytical technique for the determination and identification of metal ions even in traces. The ion-selective electrodes (ISEs) are of wide spread interest because of their simplicity, low cost, sufficiently reliable and reasonable selectivity, nondestructiveness and fast provision for analytical results (Oesch et al 1978). Precipitate based ion-selective membrane electrodes are well known as they are successfully used for the determination of several anions and cations (Amini et al 1999a, b;Li et al 1999;Hassan et al 2000;Lindfors and Ivaska 2000;Ganjali et al 2001;Shamsipur et al 2001).…”
Section: Introductionmentioning
confidence: 99%