2006
DOI: 10.1016/j.snb.2005.12.021
|View full text |Cite
|
Sign up to set email alerts
|

Ion-selective electrode for the determination of some multidrug resistance reversers

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
4
1

Citation Types

0
9
0

Year Published

2007
2007
2019
2019

Publication Types

Select...
10

Relationship

1
9

Authors

Journals

citations
Cited by 33 publications
(9 citation statements)
references
References 21 publications
0
9
0
Order By: Relevance
“…The polished electrode surface was coated with the active membrane by dipping the exposed end into the coating solution that was described under (2.5. membrane composition), ten times and allowing the film left on graphite rod to dry in air for 1 min each time. The prepared electrode was preconditioned by soaking for 6 h in 1.0 x 10 -3 mol L -1 SIM solution [16]. All potentiometric measurements were performed using the following cell assembly: Graphite rode / membrane / test solution // KCl salt bridge // SCE.…”
Section: Coated Graphite Electrodementioning
confidence: 99%
“…The polished electrode surface was coated with the active membrane by dipping the exposed end into the coating solution that was described under (2.5. membrane composition), ten times and allowing the film left on graphite rod to dry in air for 1 min each time. The prepared electrode was preconditioned by soaking for 6 h in 1.0 x 10 -3 mol L -1 SIM solution [16]. All potentiometric measurements were performed using the following cell assembly: Graphite rode / membrane / test solution // KCl salt bridge // SCE.…”
Section: Coated Graphite Electrodementioning
confidence: 99%
“…It depends on non-aqueous potentiometric titrimetry or spectrophotometry in the UV region [7,8]. Different analytical methods and techniques have been developed for Cpn determination, including chromatographic [9][10][11], potentiometric [12][13][14][15], voltammetric [16,17], fluorimetric [18][19][20], and UV-visible spectrophotometric [21][22][23][24] techniques. Quantitative analysis, using UV-visible absorption spectroscopy, is one of the most widely used methods [25,26].…”
Section: Introductionmentioning
confidence: 99%
“…Ion exchangers and neutral macrocyclic compounds have been employed over the past decades for this purpose. To our knowledge, the only two CPZ selective electrodes reported in literature [43,44] employed ion-exchangers as sensing materials.…”
Section: Introductionmentioning
confidence: 99%